Abstract

For reducing the magnitude of stray current, the diode-grounded system is an improvement over the solidly grounded system, but the rail potential and stray current remain large. However, since the diode device of this system provides a path for stray current, the magnitude of the stray current can be easily and conveniently monitored, and positive-pole earth faults can be inspected. A novel control scheme is proposed. The output voltage of the traction substation is controlled such that it remains constant in the diode-grounded system, thus the magnitude of rail potential and stray current can be reduced. Kaohsiung MRT systems are used as an example of simulating multiple traction substations and multiple trains. The simulation results show that this novel control scheme can greatly reduce the stray current and rail potential.

About this research paper

What this paper is about

For reducing the magnitude of stray current, the diode-grounded system is an improvement over the solidly grounded system, but the rail potential and stray current remain large. However, since the diode device of this system provides a path for stray current, the magnitude of the stray current can be easily and conveniently monitored, and positive-pole earth faults can be inspected. A novel control scheme is proposed. The output voltage of the traction substation is controlled such that it remains constant in the diode-grounded system, thus the magnitude of rail potential and stray current can be reduced. Kaohsiung MRT systems are used as an example of simulating multiple traction substations and multiple trains. The simulation results show that this novel control scheme can greatly reduce the stray current and rail potential.

Why it matters

OpenAlex reports 36 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

For reducing the magnitude of stray current, the diode-grounded system is an improvement over the solidly grounded system, but the rail potential and stray current remain large. However, since the diode device of this system provides a path for stray current, the magnitude of the stray current can be easily and conveniently monitored, and positive-pole earth faults can be inspected. A novel control scheme is proposed. The output voltage of the traction substation is controlled such that it remains constant in the diode-grounded system, thus the magnitude of rail potential and stray current can be reduced. Kaohsiung MRT systems are used as an example of simulating multiple traction substations and multiple trains. The simulation results show that this novel control scheme can greatly reduce the stray current and rail potential.

Key concepts: Stray voltage, Traction substation, Current (fluid), Traction (geology), Voltage, Engineering, Constant current, Diode