Comparison of Two Different Scheimpflug Devices in the Detection of Keratoconus, Regular Astigmatism, and Healthy Corneas
David Finis, Bernhard Ralla, Maria Karbe, Maria Pia Borrelli, Stefan Schrader, Gerd Geerling
Abstract
Open-access reader
David Finis, Bernhard Ralla, Maria Karbe, Maria Pia Borrelli, Stefan Schrader, Gerd Geerling
Abstract
Open-access reader
Aim. The aim of this study was to determine the intra- and interobserver variability of two Scheimpflug based camera systems, Pentacam and Sirius. In addition, the comparability of the measurements was tested in healthy subjects, subjects with regular astigmatism, and keratoconus patients. Methods. Intra- and interobserver variability were assessed in 20 healthy corneas. Pachymetry values were also compared with ultrasound pachymetry as a reference measurement. To detect possible differences between the two devices, 82 eyes with clinically established keratoconus, 30 eyes with regular astigmatism (>1.5 D), and 60 eyes without corneal pathologies were included in this prospective study. Results. Pachymetry and keratometry showed good intra- and interobserver variability for both devices. Pachymetry values obtained with the Sirius system (579 ± 58 μm) were significantly higher compared to the Pentacam system (551 ± 40 μm, P < 0.001) and to ultrasound pachymetry (550 ± 43 μm, P < 0.001). Significant interdevice differences were found regarding the majority of the detected keratometry parameters. Conclusions. Both devices show almost perfect reproducibility in healthy subjects. However, pachymetry and keratometry values of the two devices should not be used interchangeably.
OpenAlex reports 30 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
Aim. The aim of this study was to determine the intra- and interobserver variability of two Scheimpflug based camera systems, Pentacam and Sirius. In addition, the comparability of the measurements was tested in healthy subjects, subjects with regular astigmatism, and keratoconus patients. Methods. Intra- and interobserver variability were assessed in 20 healthy corneas. Pachymetry values were also compared with ultrasound pachymetry as a reference measurement. To detect possible differences between the two devices, 82 eyes with clinically established keratoconus, 30 eyes with regular astigmatism (>1.5 D), and 60 eyes without corneal pathologies were included in this prospective study. Results. Pachymetry and keratometry showed good intra- and interobserver variability for both devices. Pachymetry values obtained with the Sirius system (579 ± 58 μm) were significantly higher compared to the Pentacam system (551 ± 40 μm, P < 0.001) and to ultrasound pachymetry (550 ± 43 μm, P < 0.001). Significant interdevice differences were found regarding the majority of the detected keratometry parameters. Conclusions. Both devices show almost perfect reproducibility in healthy subjects. However, pachymetry and keratometry values of the two devices should not be used interchangeably.
Key concepts: Scheimpflug principle, Keratometer, Sirius, Keratoconus, Medicine, Algorithm, Astigmatism, Ophthalmology