Comparative Evaluation of Central Corneal Thickness in Cross-Linked Keratoconic Eyes

Pınar Kösekahya, Mustafa Koç, Kübra Özdemir Yalçınsoy, Dilara Özkoyuncu Kocabaş, Mustafa Toker

Open publisher page 8 citations

Abstract

PURPOSE: To compare the central corneal thickness (CCT) measurements measured by using the Pentacam Scheimpflug system with the CCT measured using ultrasound pachymetry (UP) and to compare the compatibility between the methods in normal, keratoconic, and cross-linked keratoconic corneas. METHODS: The study included 50 eyes of 50 patients with keratoconus (keratoconus group), 50 eyes of 50 patients with progressive keratoconus who underwent corneal cross-linking treatment (CCL group), and 50 eyes of 50 healthy subjects (control group). Patients in the keratoconus and CCL groups were further classified into mild (mean keratometry [Km] ≤ 47 D) and moderate keratoconus subgroups (47.0 < Km < 52.0 D). CCT values were noted from the Pentacam Scheimpflug and UP. RESULTS: The difference between the Pentacam and UP values was largest in the CCL group (-20.9 0.21.5 μm), followed by the keratoconus and control groups (-10.6 0.20.3 and 0.4 0.6.8 μm). The Pentacam and UP measurements were not comparable in the keratoconus and CCL groups (P = 0.001 and P < 0.001), whereas they were comparable in the control group (P = 0.62). In subgroup analysis, the 2 methods were comparable in the mild keratoconus subgroup (P = 0.12) and not comparable in the moderate keratoconus subgroup and in both mild and moderate subgroups of the CCL group (P = 0.001, P < 0.001 and P < 0.001). CONCLUSIONS: Pentacam Scheimpflug tomography and UP can be used interchangeably in normal and mild keratoconic eyes, but not in moderate keratoconic and cross-linked keratoconic eyes. Pachymetry measurements from Scheimpflug must be interpreted with extreme caution with different methods before planning an invasive procedure in these eyes.

About this research paper

What this paper is about

PURPOSE: To compare the central corneal thickness (CCT) measurements measured by using the Pentacam Scheimpflug system with the CCT measured using ultrasound pachymetry (UP) and to compare the compatibility between the methods in normal, keratoconic, and cross-linked keratoconic corneas. METHODS: The study included 50 eyes of 50 patients with keratoconus (keratoconus group), 50 eyes of 50 patients with progressive keratoconus who underwent corneal cross-linking treatment (CCL group), and 50 eyes of 50 healthy subjects (control group). Patients in the keratoconus and CCL groups were further classified into mild (mean keratometry [Km] ≤ 47 D) and moderate keratoconus subgroups (47.0 < Km < 52.0 D). CCT values were noted from the Pentacam Scheimpflug and UP. RESULTS: The difference between the Pentacam and UP values was largest in the CCL group (-20.9 0.21.5 μm), followed by the keratoconus and control groups (-10.6 0.20.3 and 0.4 0.6.8 μm). The Pentacam and UP measurements were not comparable in the keratoconus and CCL groups (P = 0.001 and P < 0.001), whereas they were comparable in the control group (P = 0.62). In subgroup analysis, the 2 methods were comparable in the mild keratoconus subgroup (P = 0.12) and not comparable in the moderate keratoconus subgroup and in both mild and moderate subgroups of the CCL group (P = 0.001, P < 0.001 and P < 0.001). CONCLUSIONS: Pentacam Scheimpflug tomography and UP can be used interchangeably in normal and mild keratoconic eyes, but not in moderate keratoconic and cross-linked keratoconic eyes. Pachymetry measurements from Scheimpflug must be interpreted with extreme caution with different methods before planning an invasive procedure in these eyes.

Why it matters

OpenAlex reports 8 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

PURPOSE: To compare the central corneal thickness (CCT) measurements measured by using the Pentacam Scheimpflug system with the CCT measured using ultrasound pachymetry (UP) and to compare the compatibility between the methods in normal, keratoconic, and cross-linked keratoconic corneas. METHODS: The study included 50 eyes of 50 patients with keratoconus (keratoconus group), 50 eyes of 50 patients with progressive keratoconus who underwent corneal cross-linking treatment (CCL group), and 50 eyes of 50 healthy subjects (control group). Patients in the keratoconus and CCL groups were further classified into mild (mean keratometry [Km] ≤ 47 D) and moderate keratoconus subgroups (47.0 < Km < 52.0 D). CCT values were noted from the Pentacam Scheimpflug and UP. RESULTS: The difference between the Pentacam and UP values was largest in the CCL group (-20.9 0.21.5 μm), followed by the keratoconus and control groups (-10.6 0.20.3 and 0.4 0.6.8 μm). The Pentacam and UP measurements were not comparable in the keratoconus and CCL groups (P = 0.001 and P < 0.001), whereas they were comparable in the control group (P = 0.62). In subgroup analysis, the 2 methods were comparable in the mild keratoconus subgroup (P = 0.12) and not comparable in the moderate keratoconus subgroup and in both mild and moderate subgroups of the CCL group (P = 0.001, P < 0.001 and P < 0.001). CONCLUSIONS: Pentacam Scheimpflug tomography and UP can be used interchangeably in normal and mild keratoconic eyes, but not in moderate keratoconic and cross-linked keratoconic eyes. Pachymetry measurements from Scheimpflug must be interpreted with extreme caution with different methods before planning an invasive procedure in these eyes.

Key concepts: Ophthalmology, Keratoconus, Medicine, Optometry, Corneal topography, Cornea

Related papers

Back to paper searchBrowse research topicsOriginal source
Comparative Evaluation of Central Corneal Thickness in Cross-Linked Keratoconic Eyes — Research Paper | ScholarLens