Fault analysis of distribution network with wind turbines of DFIG

Yang Beige, Xue Hui, Bai Dan-dan, Wei Hu, He Jinghan

Open publisher page 0 citations

Abstract

With high penetrations of wind energy, different types of wind farm generators do not have the same fault transient characteristics that can complicate the selection and configuration of wind farm grid protection equipment. Incorrect selection of protection equipment will affect the stability and of the power systems. This paper investigates and analyzes the transient characteristics of doubly-fed induction generator (DFIG) under various short-circuit fault conditions for a typical distribution network. Firstly a detailed model of the DFIG and its principles is descried. A realistic of a 99 MW wind farm with 66 units of 1.5 MW DFIG is modeled using RTDS/RSCAD. The transient characteristic of the wind farm with the DFIG units have been analyzed under different short-circuit fault conditions. Results from the fault performance study on the distribution network are presented and discussed.

About this research paper

What this paper is about

With high penetrations of wind energy, different types of wind farm generators do not have the same fault transient characteristics that can complicate the selection and configuration of wind farm grid protection equipment. Incorrect selection of protection equipment will affect the stability and of the power systems. This paper investigates and analyzes the transient characteristics of doubly-fed induction generator (DFIG) under various short-circuit fault conditions for a typical distribution network. Firstly a detailed model of the DFIG and its principles is descried. A realistic of a 99 MW wind farm with 66 units of 1.5 MW DFIG is modeled using RTDS/RSCAD. The transient characteristic of the wind farm with the DFIG units have been analyzed under different short-circuit fault conditions. Results from the fault performance study on the distribution network are presented and discussed.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

With high penetrations of wind energy, different types of wind farm generators do not have the same fault transient characteristics that can complicate the selection and configuration of wind farm grid protection equipment. Incorrect selection of protection equipment will affect the stability and of the power systems. This paper investigates and analyzes the transient characteristics of doubly-fed induction generator (DFIG) under various short-circuit fault conditions for a typical distribution network. Firstly a detailed model of the DFIG and its principles is descried. A realistic of a 99 MW wind farm with 66 units of 1.5 MW DFIG is modeled using RTDS/RSCAD. The transient characteristic of the wind farm with the DFIG units have been analyzed under different short-circuit fault conditions. Results from the fault performance study on the distribution network are presented and discussed.

Key concepts: Doubly fed electric machine, Wind power, Transient (computer programming), Fault (geology), Induction generator, Control theory (sociology), Engineering, Power (physics)

Related papers

Back to paper searchBrowse research topicsOriginal source
Fault analysis of distribution network with wind turbines of DFIG — Research Paper | ScholarLens