The use of an electronic portal imaging system to measure portal dose and portal dose profiles
Homayoon Parsaei, Ellen El‐Khatib, Rasika Rajapakshe
Abstract
Homayoon Parsaei, Ellen El‐Khatib, Rasika Rajapakshe
Abstract
The dosimetric characteristics of a scanning liquid-filled ionization chamber (SLIC) electronic portal imaging device have been investigated. To assess the system's response in relation to incident radiation beam intensity, a series of characteristic curves are obtained for various field sizes and nominal energies of 6 and 10 MV photons. The response of the imaging system is dependent on incident radiation intensity and can be described to within 1% accuracy on central axis using a square root function. Portal dose measurements with the SLIC at the plane of the detector, on central axis of the beam using homogeneous attenuating phantom materials show that the imaging system is capable of measuring the portal (transmission) dose to within 3% of the ionization chamber results for homogeneous material. For two-dimensional dosimetry applications, the system is calibrated with a 10 cm Perspex block used as beam flattening material on the detector cassette to correct for variations in individual ion chamber sensitivity and the effect of nonuniform beam profiles produced by the flattening filter. Open and wedged dose profiles measured with the SLIC agreed with ion chamber measured profiles to within 3.5% accuracy.
OpenAlex reports 37 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
The dosimetric characteristics of a scanning liquid-filled ionization chamber (SLIC) electronic portal imaging device have been investigated. To assess the system's response in relation to incident radiation beam intensity, a series of characteristic curves are obtained for various field sizes and nominal energies of 6 and 10 MV photons. The response of the imaging system is dependent on incident radiation intensity and can be described to within 1% accuracy on central axis using a square root function. Portal dose measurements with the SLIC at the plane of the detector, on central axis of the beam using homogeneous attenuating phantom materials show that the imaging system is capable of measuring the portal (transmission) dose to within 3% of the ionization chamber results for homogeneous material. For two-dimensional dosimetry applications, the system is calibrated with a 10 cm Perspex block used as beam flattening material on the detector cassette to correct for variations in individual ion chamber sensitivity and the effect of nonuniform beam profiles produced by the flattening filter. Open and wedged dose profiles measured with the SLIC agreed with ion chamber measured profiles to within 3.5% accuracy.
Key concepts: Ionization chamber, Dosimetry, Dose profile, Detector, Imaging phantom, Optics, Percentage depth dose curve, Beam (structure)