1994Acta Anaesthesiologica ScandinavicaRequires access

Somatosensory evoked potentials during isoflurane anaesthesia

Timo Porkkala, V. Jäntti, Seppo Kaukinen, V. Häkkinen

Open publisher page 19 citations

Abstract

Short latency somatosensory evoked potentials (SEPs) to median nerve stimulation during isoflurane anaesthesia were recorded in 12 elective-surgery patients. The effect of isoflurane on the shape, amplitude and latency of SEPs was evaluated. SEPs were recorded at awake, 1 MAC, 1.5 MAC, at electroencephalogram (EEG) burst suppression and at continuous suppression levels. Finally, SEPs were recorded when anaesthesia was lightened back to 1 MAC. The peak latency and amplitude of the first cortical N20 wave were measured. The latencies increased with increasing isoflurane concentrations. At high concentrations only an almost monophasic N20 wave was recorded, reduced in shape and amplitude. No specific changes could be correlated with the burst suppression or suppression patterns. This suggests that EEG and SEP generators are differently affected with increasing isoflurane concentration. The results indicate that SEPs can also be recorded in drug-induced EEG suppression.

About this research paper

What this paper is about

Short latency somatosensory evoked potentials (SEPs) to median nerve stimulation during isoflurane anaesthesia were recorded in 12 elective-surgery patients. The effect of isoflurane on the shape, amplitude and latency of SEPs was evaluated. SEPs were recorded at awake, 1 MAC, 1.5 MAC, at electroencephalogram (EEG) burst suppression and at continuous suppression levels. Finally, SEPs were recorded when anaesthesia was lightened back to 1 MAC. The peak latency and amplitude of the first cortical N20 wave were measured. The latencies increased with increasing isoflurane concentrations. At high concentrations only an almost monophasic N20 wave was recorded, reduced in shape and amplitude. No specific changes could be correlated with the burst suppression or suppression patterns. This suggests that EEG and SEP generators are differently affected with increasing isoflurane concentration. The results indicate that SEPs can also be recorded in drug-induced EEG suppression.

Why it matters

OpenAlex reports 19 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Short latency somatosensory evoked potentials (SEPs) to median nerve stimulation during isoflurane anaesthesia were recorded in 12 elective-surgery patients. The effect of isoflurane on the shape, amplitude and latency of SEPs was evaluated. SEPs were recorded at awake, 1 MAC, 1.5 MAC, at electroencephalogram (EEG) burst suppression and at continuous suppression levels. Finally, SEPs were recorded when anaesthesia was lightened back to 1 MAC. The peak latency and amplitude of the first cortical N20 wave were measured. The latencies increased with increasing isoflurane concentrations. At high concentrations only an almost monophasic N20 wave was recorded, reduced in shape and amplitude. No specific changes could be correlated with the burst suppression or suppression patterns. This suggests that EEG and SEP generators are differently affected with increasing isoflurane concentration. The results indicate that SEPs can also be recorded in drug-induced EEG suppression.

Key concepts: Medicine, Isoflurane, Anesthesia, Somatosensory evoked potential

Related papers

Back to paper searchBrowse research topicsOriginal source
Somatosensory evoked potentials during isoflurane anaesthesia — Research Paper | ScholarLens