2008Unpublished venueRequires access

Characteristics of the 250MW Pebble-Bed Modular High Temperature Gas-Cooled Reactor in Depressurized Loss of Coolant Accidents

Yanhua Zhengy, Lei Shi

Open publisher page 12 citations

Abstract

Depressurized loss of coolant accident (DLOCA) is one of the most important design basis accidents for high temperature gas-cooled reactors. Analysis of the reactor characteristic behavior during DLOCA can provide useful reference to the physics, thermo-hydraulic and structure designs of the reactor core. In this paper, according to the preliminary design of the 250MW Pebble-bed Modular High Temperature Gas-cooled Reactor (HTR-PM), three cases of DLOCA: a instantaneous depressurization along with a flow coastdown and scram at zero time, a main pipe with a diameter of 65mm rupture, and a instrument pipe with a diameter of 10mm broken, are studied by the help of two different kinds of software THERMIX and TINTE. The key parameters of different cases including reactor power, temperature distribution of the core and pressure vessel, and the decay power removal by the passive residual heat remove system (RHRS) are compared in detail. Some uncertainties, such as residual heat calculation, power distribution, heat conductivity of fuel element, etc., are analyzed in order to evaluate the safety margin of the maximum fuel temperature during DLOCA. The calculating results show that, the decay heat in the DLOCA can be removed from the reactor core solely by means of physical processes in a passive way, so that the temperature limits of fuel and components are still obeyed. It also illustrates that the HTR-PM can reach 250MW reactor power per unit and still can keep the inherent safety.

About this research paper

What this paper is about

Depressurized loss of coolant accident (DLOCA) is one of the most important design basis accidents for high temperature gas-cooled reactors. Analysis of the reactor characteristic behavior during DLOCA can provide useful reference to the physics, thermo-hydraulic and structure designs of the reactor core. In this paper, according to the preliminary design of the 250MW Pebble-bed Modular High Temperature Gas-cooled Reactor (HTR-PM), three cases of DLOCA: a instantaneous depressurization along with a flow coastdown and scram at zero time, a main pipe with a diameter of 65mm rupture, and a instrument pipe with a diameter of 10mm broken, are studied by the help of two different kinds of software THERMIX and TINTE. The key parameters of different cases including reactor power, temperature distribution of the core and pressure vessel, and the decay power removal by the passive residual heat remove system (RHRS) are compared in detail. Some uncertainties, such as residual heat calculation, power distribution, heat conductivity of fuel element, etc., are analyzed in order to evaluate the safety margin of the maximum fuel temperature during DLOCA. The calculating results show that, the decay heat in the DLOCA can be removed from the reactor core solely by means of physical processes in a passive way, so that the temperature limits of fuel and components are still obeyed. It also illustrates that the HTR-PM can reach 250MW reactor power per unit and still can keep the inherent safety.

Why it matters

OpenAlex reports 12 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Depressurized loss of coolant accident (DLOCA) is one of the most important design basis accidents for high temperature gas-cooled reactors. Analysis of the reactor characteristic behavior during DLOCA can provide useful reference to the physics, thermo-hydraulic and structure designs of the reactor core. In this paper, according to the preliminary design of the 250MW Pebble-bed Modular High Temperature Gas-cooled Reactor (HTR-PM), three cases of DLOCA: a instantaneous depressurization along with a flow coastdown and scram at zero time, a main pipe with a diameter of 65mm rupture, and a instrument pipe with a diameter of 10mm broken, are studied by the help of two different kinds of software THERMIX and TINTE. The key parameters of different cases including reactor power, temperature distribution of the core and pressure vessel, and the decay power removal by the passive residual heat remove system (RHRS) are compared in detail. Some uncertainties, such as residual heat calculation, power distribution, heat conductivity of fuel element, etc., are analyzed in order to evaluate the safety margin of the maximum fuel temperature during DLOCA. The calculating results show that, the decay heat in the DLOCA can be removed from the reactor core solely by means of physical processes in a passive way, so that the temperature limits of fuel and components are still obeyed. It also illustrates that the HTR-PM can reach 250MW reactor power per unit and still can keep the inherent safety.

Key concepts: Nuclear engineering, Decay heat, Coolant, Scram, Nuclear reactor core, Reactor pressure vessel, Cabin pressurization, Pressurizer

Related papers

Back to paper searchBrowse research topicsOriginal source
Characteristics of the 250MW Pebble-Bed Modular High Temperature Gas-Cooled Reactor in Depressurized Loss of Coolant Accidents — Research Paper | ScholarLens