2004Journal of Environmental Science and Health Part ARequires access

Application of Granular Media Filtration in Wastewater Reclamation and Reuse

Mohamed F. Hamoda, Ibrahim A. Al-Ghusain, D. M. Al-Jasem

Open publisher page 21 citations

Abstract

Laboratory experiments were conducted at room temperature (20-25 degrees C) using four identical filter columns made of Plexiglas, each of 1 m height and 15 cm internal diameter, packed with granular media of 70 cm depth. Each filter was operated at a constant filtration rate, thus four rates were tested in the range of 2-15 m(3) m(-2) d(-1). Mono-media (sand) and dual-media (sand and anthracite) were tested and three types of municipal wastewaters, namely raw, primary and secondary-treated effluents were applied. The results obtained indicate that considerable improvements in effluent quality could be attained by tertiary sand filtration. Removal of solids, organics and bacteria was not significantly affected by the increase in filtration rate from 2 to 15 m(3) m(-2) d(-1). The highest removal efficiency was obtained at low filtration rate of 2 m(3) m(-2) d(-1), but higher filtration rates achieved acceptable removal efficiencies and provided effluents of good quality to satisfy the irrigation water quality standards. Since the conventional sand filters in wastewater treatment plants operate at a rate in the range of 2-5 m(3) m(-2) d(-1), utilization of high rate filtration is advantageous and would result in significant cost savings. However, with high filtration rates the filters require more frequent backwashing. Dual-media filters achieved 50% reductions in BOD suggesting that filtration could be used to treat primary effluents in emergency cases.

About this research paper

What this paper is about

Laboratory experiments were conducted at room temperature (20-25 degrees C) using four identical filter columns made of Plexiglas, each of 1 m height and 15 cm internal diameter, packed with granular media of 70 cm depth. Each filter was operated at a constant filtration rate, thus four rates were tested in the range of 2-15 m(3) m(-2) d(-1). Mono-media (sand) and dual-media (sand and anthracite) were tested and three types of municipal wastewaters, namely raw, primary and secondary-treated effluents were applied. The results obtained indicate that considerable improvements in effluent quality could be attained by tertiary sand filtration. Removal of solids, organics and bacteria was not significantly affected by the increase in filtration rate from 2 to 15 m(3) m(-2) d(-1). The highest removal efficiency was obtained at low filtration rate of 2 m(3) m(-2) d(-1), but higher filtration rates achieved acceptable removal efficiencies and provided effluents of good quality to satisfy the irrigation water quality standards. Since the conventional sand filters in wastewater treatment plants operate at a rate in the range of 2-5 m(3) m(-2) d(-1), utilization of high rate filtration is advantageous and would result in significant cost savings. However, with high filtration rates the filters require more frequent backwashing. Dual-media filters achieved 50% reductions in BOD suggesting that filtration could be used to treat primary effluents in emergency cases.

Why it matters

OpenAlex reports 21 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Laboratory experiments were conducted at room temperature (20-25 degrees C) using four identical filter columns made of Plexiglas, each of 1 m height and 15 cm internal diameter, packed with granular media of 70 cm depth. Each filter was operated at a constant filtration rate, thus four rates were tested in the range of 2-15 m(3) m(-2) d(-1). Mono-media (sand) and dual-media (sand and anthracite) were tested and three types of municipal wastewaters, namely raw, primary and secondary-treated effluents were applied. The results obtained indicate that considerable improvements in effluent quality could be attained by tertiary sand filtration. Removal of solids, organics and bacteria was not significantly affected by the increase in filtration rate from 2 to 15 m(3) m(-2) d(-1). The highest removal efficiency was obtained at low filtration rate of 2 m(3) m(-2) d(-1), but higher filtration rates achieved acceptable removal efficiencies and provided effluents of good quality to satisfy the irrigation water quality standards. Since the conventional sand filters in wastewater treatment plants operate at a rate in the range of 2-5 m(3) m(-2) d(-1), utilization of high rate filtration is advantageous and would result in significant cost savings. However, with high filtration rates the filters require more frequent backwashing. Dual-media filters achieved 50% reductions in BOD suggesting that filtration could be used to treat primary effluents in emergency cases.

Key concepts: Effluent, Filtration (mathematics), Backwashing, Wastewater, Environmental engineering, Pulp and paper industry, Suspended solids, Filter (signal processing)

Related papers

Back to paper searchBrowse research topicsOriginal source
Application of Granular Media Filtration in Wastewater Reclamation and Reuse — Research Paper | ScholarLens