2008International Journal of Energy ResearchOpen access

Performance and exergetic analysis of vapor compression refrigeration system with an internal heat exchanger using a hydrocarbon, isobutane (R600a)

Ahmet Kabul, Önder Kızılkan, Ali Kemal Yakut

Open full text 75 citations

Abstract

Hydrocarbons (HCs) are excellent refrigerants in many ways such as energy efficiency, critical point, solubility, transport and heat transfer properties, but they are also flammable, which causes the need for changes in standards, production and product. There are increasing number of scientists and engineers who believe that an alternative solution, which has been overlooked, may be provided by using HCs. The main objective of this study is to perform energy and exergy analyses for a vapor compression refrigeration system with an internal heat exchanger using a HC, isobutene (R600a). For a refrigeration capacity of 1 kW and cold chamber temperature of 0°C, energy and exergy balances are taken into account to determine the performance of the refrigeration system. Energy and exergy fluxes are determined, and irreversibility rates are calculated for every component of the system. It is seen that the compressor has the highest irreversibility rate, and the heat exchanger has the lowest. Also from the result of the analysis, it is found that condenser and evaporator temperatures have strong effects on energetic and exergetic performances of the system such as coefficient of performance (COP), efficiency ratio (τ), exergetic efficiency (ξ) and irreversibility rate. Copyright © 2008 John Wiley & Sons, Ltd.

Open-access reader

About this research paper

What this paper is about

Hydrocarbons (HCs) are excellent refrigerants in many ways such as energy efficiency, critical point, solubility, transport and heat transfer properties, but they are also flammable, which causes the need for changes in standards, production and product. There are increasing number of scientists and engineers who believe that an alternative solution, which has been overlooked, may be provided by using HCs. The main objective of this study is to perform energy and exergy analyses for a vapor compression refrigeration system with an internal heat exchanger using a HC, isobutene (R600a). For a refrigeration capacity of 1 kW and cold chamber temperature of 0°C, energy and exergy balances are taken into account to determine the performance of the refrigeration system. Energy and exergy fluxes are determined, and irreversibility rates are calculated for every component of the system. It is seen that the compressor has the highest irreversibility rate, and the heat exchanger has the lowest. Also from the result of the analysis, it is found that condenser and evaporator temperatures have strong effects on energetic and exergetic performances of the system such as coefficient of performance (COP), efficiency ratio (τ), exergetic efficiency (ξ) and irreversibility rate. Copyright © 2008 John Wiley & Sons, Ltd.

Why it matters

OpenAlex reports 75 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Hydrocarbons (HCs) are excellent refrigerants in many ways such as energy efficiency, critical point, solubility, transport and heat transfer properties, but they are also flammable, which causes the need for changes in standards, production and product. There are increasing number of scientists and engineers who believe that an alternative solution, which has been overlooked, may be provided by using HCs. The main objective of this study is to perform energy and exergy analyses for a vapor compression refrigeration system with an internal heat exchanger using a HC, isobutene (R600a). For a refrigeration capacity of 1 kW and cold chamber temperature of 0°C, energy and exergy balances are taken into account to determine the performance of the refrigeration system. Energy and exergy fluxes are determined, and irreversibility rates are calculated for every component of the system. It is seen that the compressor has the highest irreversibility rate, and the heat exchanger has the lowest. Also from the result of the analysis, it is found that condenser and evaporator temperatures have strong effects on energetic and exergetic performances of the system such as coefficient of performance (COP), efficiency ratio (τ), exergetic efficiency (ξ) and irreversibility rate. Copyright © 2008 John Wiley & Sons, Ltd.

Key concepts: Exergy, Refrigeration, Thermodynamics, Condenser (optics), Heat exchanger, Coefficient of performance, Vapor-compression refrigeration, Exergy efficiency

Related papers

Back to paper searchBrowse research topicsOriginal source
Performance and exergetic analysis of vapor compression refrigeration system with an internal heat exchanger using a hydrocarbon, isobutane (R600a) — Research Paper | ScholarLens