Prospect of hydrocarbon uses based on exergy analysis in the vapor compression refrigeration system
Jamal Uddin Ahamed, R. Saidur, H.H. Masjuki
Abstract
Jamal Uddin Ahamed, R. Saidur, H.H. Masjuki
Abstract
This paper emphasized on the possibilities of researches in the field of exergy analysis in various usable sectors where vapor compression refrigeration systems are used. Exergy losses, exergy efficiency, second law efficiency and irreversibility of the system components as well as of the whole system are measured. In the vapor compression system, R134a, R290 and R600a are considered as refrigerants. Exergy parameters in the compressor, evaporator, condenser and expansion devices are calculated and analyzed. Exergy losses depend on evaporator temperatures, condensing temperature, refrigerants and ambient temperature. Most of the exergy losses occur in the condenser. Expansion device has the lowest losses. Exergy parameters are compared for different operating temperature. It is found that hydrocarbons (R600a) have 50% higher exergy efficiency than R134a. Mixture of hydrocarbons also shows the best performance based on the exergy analysis.
OpenAlex reports 11 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
This paper emphasized on the possibilities of researches in the field of exergy analysis in various usable sectors where vapor compression refrigeration systems are used. Exergy losses, exergy efficiency, second law efficiency and irreversibility of the system components as well as of the whole system are measured. In the vapor compression system, R134a, R290 and R600a are considered as refrigerants. Exergy parameters in the compressor, evaporator, condenser and expansion devices are calculated and analyzed. Exergy losses depend on evaporator temperatures, condensing temperature, refrigerants and ambient temperature. Most of the exergy losses occur in the condenser. Expansion device has the lowest losses. Exergy parameters are compared for different operating temperature. It is found that hydrocarbons (R600a) have 50% higher exergy efficiency than R134a. Mixture of hydrocarbons also shows the best performance based on the exergy analysis.
Key concepts: Exergy, Refrigerant, Evaporator, Condenser (optics), Gas compressor, Vapor-compression refrigeration, Exergy efficiency, Refrigeration