2006Journal of Food ScienceOpen access

Inactivation Kinetics of Geobacillus stearothermophilus Spores in Water Using High‐pressure Processing at Elevated Temperatures

Eduardo Patazca, Tatiana Koutchma, Hosahalli S. Ramaswamy

Open full text 57 citations

Abstract

ABSTRACT: Establishment of a high‐pressure sterilization process requires data on pressure and temperature‐dependent inactivation kinetics of target pathogenic, spoilage, or surrogate spore‐forming bacteria in the food being tested. The objective of this study was to examine the response of Geobacillus stearothermophilus ATCC10149 spores to various temperature, time, and pressure combination treatments (500 to 700 MPa; 92°C to 111°C, 0.01 to 360 s). The pressure inactivation of spores was characterized at elevated temperatures under isobaric and isothermal conditions during the holding time using a laboratory‐scale high‐pressure unit. The inactivation kinetics was well described by the log‐linear regression model. As expected, the rate of spore inactivation increased with increasing pressure and temperature. Decimal reduction times at constant pressure ( D T,P values) varied from 29.4 to 108.8 s at 92°C, 17.4 to 76 s at 100°C, and 6.1 to 51.3 s at 111°C within the pressure range of 500 to 700 MPa. The resistance of spores to temperature and pressure was characterized with z T and z P values and compared with their resistance to conventional steam heating. The conventional thermal resistance of G. stearothermophilus species did not correlate to the thermal resistance at high pressure. The study provides kinetic data on the effects of pressure and temperature on the inactivation of a heat‐resistant bacterial spore species under conditions applicable to the commercial processing of low‐acid foods.

Open-access reader

About this research paper

What this paper is about

ABSTRACT: Establishment of a high‐pressure sterilization process requires data on pressure and temperature‐dependent inactivation kinetics of target pathogenic, spoilage, or surrogate spore‐forming bacteria in the food being tested. The objective of this study was to examine the response of Geobacillus stearothermophilus ATCC10149 spores to various temperature, time, and pressure combination treatments (500 to 700 MPa; 92°C to 111°C, 0.01 to 360 s). The pressure inactivation of spores was characterized at elevated temperatures under isobaric and isothermal conditions during the holding time using a laboratory‐scale high‐pressure unit. The inactivation kinetics was well described by the log‐linear regression model. As expected, the rate of spore inactivation increased with increasing pressure and temperature. Decimal reduction times at constant pressure ( D T,P values) varied from 29.4 to 108.8 s at 92°C, 17.4 to 76 s at 100°C, and 6.1 to 51.3 s at 111°C within the pressure range of 500 to 700 MPa. The resistance of spores to temperature and pressure was characterized with z T and z P values and compared with their resistance to conventional steam heating. The conventional thermal resistance of G. stearothermophilus species did not correlate to the thermal resistance at high pressure. The study provides kinetic data on the effects of pressure and temperature on the inactivation of a heat‐resistant bacterial spore species under conditions applicable to the commercial processing of low‐acid foods.

Why it matters

OpenAlex reports 57 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

ABSTRACT: Establishment of a high‐pressure sterilization process requires data on pressure and temperature‐dependent inactivation kinetics of target pathogenic, spoilage, or surrogate spore‐forming bacteria in the food being tested. The objective of this study was to examine the response of Geobacillus stearothermophilus ATCC10149 spores to various temperature, time, and pressure combination treatments (500 to 700 MPa; 92°C to 111°C, 0.01 to 360 s). The pressure inactivation of spores was characterized at elevated temperatures under isobaric and isothermal conditions during the holding time using a laboratory‐scale high‐pressure unit. The inactivation kinetics was well described by the log‐linear regression model. As expected, the rate of spore inactivation increased with increasing pressure and temperature. Decimal reduction times at constant pressure ( D T,P values) varied from 29.4 to 108.8 s at 92°C, 17.4 to 76 s at 100°C, and 6.1 to 51.3 s at 111°C within the pressure range of 500 to 700 MPa. The resistance of spores to temperature and pressure was characterized with z T and z P values and compared with their resistance to conventional steam heating. The conventional thermal resistance of G. stearothermophilus species did not correlate to the thermal resistance at high pressure. The study provides kinetic data on the effects of pressure and temperature on the inactivation of a heat‐resistant bacterial spore species under conditions applicable to the commercial processing of low‐acid foods.

Key concepts: Geobacillus stearothermophilus, D-value, Spore, Pascalization, Kinetics, Sterilization (economics), Chemistry, Food science

Related papers

Back to paper searchBrowse research topicsOriginal source
Inactivation Kinetics of Geobacillus stearothermophilus Spores in Water Using High‐pressure Processing at Elevated Temperatures — Research Paper | ScholarLens