2010Analytical LettersRequires access

Determination of Chlorzoxazone in Rat Plasma by LC-ESI-MS/MS and Its Application to a Pharmacokinetic Study

Xianqin Wang, Lufeng Hu, Shuhua Tong, Yangming Zheng, Faqing Ye, Dan Lin, Guanyang Lin, Xun Zhang, Haiya Wu

Open publisher page 10 citations

Abstract

A sensitive LC-ESI-MS/MS method for determination of chlorzoxazone in rat plasma has been developed. Chromatographic separation was achieved on a Zorbax SB-C18 column, with 45:55 (v/v) acetonitrile–water as the mobile phase. A LC-ESI-MS/MS was performed in a multiple reactions monitoring (MRM) mode using target ions m/z 167.5→131.6 for chlorzoxazone and m/z 230.7→185.6 for phenobarbital (internal standard). The calibration plots were linear over the range of 10.0–2,000 ng/mL. Intra-day and inter-day precisions were better than 5.1% and 6.8%, respectively. The validated method was successfully used to analyze the drug in samples of rat plasma for pharmacokinetic study.

About this research paper

What this paper is about

A sensitive LC-ESI-MS/MS method for determination of chlorzoxazone in rat plasma has been developed. Chromatographic separation was achieved on a Zorbax SB-C18 column, with 45:55 (v/v) acetonitrile–water as the mobile phase. A LC-ESI-MS/MS was performed in a multiple reactions monitoring (MRM) mode using target ions m/z 167.5→131.6 for chlorzoxazone and m/z 230.7→185.6 for phenobarbital (internal standard). The calibration plots were linear over the range of 10.0–2,000 ng/mL. Intra-day and inter-day precisions were better than 5.1% and 6.8%, respectively. The validated method was successfully used to analyze the drug in samples of rat plasma for pharmacokinetic study.

Why it matters

OpenAlex reports 10 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A sensitive LC-ESI-MS/MS method for determination of chlorzoxazone in rat plasma has been developed. Chromatographic separation was achieved on a Zorbax SB-C18 column, with 45:55 (v/v) acetonitrile–water as the mobile phase. A LC-ESI-MS/MS was performed in a multiple reactions monitoring (MRM) mode using target ions m/z 167.5→131.6 for chlorzoxazone and m/z 230.7→185.6 for phenobarbital (internal standard). The calibration plots were linear over the range of 10.0–2,000 ng/mL. Intra-day and inter-day precisions were better than 5.1% and 6.8%, respectively. The validated method was successfully used to analyze the drug in samples of rat plasma for pharmacokinetic study.

Key concepts: Chlorzoxazone, Chemistry, Chromatography, Pharmacokinetics, Calibration curve, Acetonitrile, Analytical Chemistry (journal), Detection limit

Related papers

Back to paper searchBrowse research topicsOriginal source
Determination of Chlorzoxazone in Rat Plasma by LC-ESI-MS/MS and Its Application to a Pharmacokinetic Study — Research Paper | ScholarLens