Short-Term Changes in Ocular Biometry and Refraction After Discontinuation of Long-Term Orthokeratology
Jacinto Santodomingo‐Rubido, César Villa-Collar, Bernard Gilmartin, Ramón Gutiérrez-Ortega
Abstract
Jacinto Santodomingo‐Rubido, César Villa-Collar, Bernard Gilmartin, Ramón Gutiérrez-Ortega
Abstract
OBJECTIVE: To assess refractive and biometric changes 1 week after discontinuation of lens wear in subjects who had been wearing orthokeratology (OK) contact lenses for 2 years. METHODS: Twenty-nine subjects aged 6 to 12 years and with myopia of -0.75 to -4.00 diopters (D) and astigmatism of ≤1.00 D participated in the study. Measurements of axial length and anterior chamber depth (Zeiss IOLMaster), corneal power and shape, and cycloplegic refraction were taken 1 week after discontinuation and compared with those at baseline and after 24 months of lens wear. RESULTS: A hyperopic shift was found at 24 months relative to baseline in spherical equivalent refractive error (+1.86±1.01 D), followed by a myopic shift at 1 week relative to 24 months (-1.93±0.92 D) (both P<0.001). Longer axial lengths were found at 24 months and 1 week in comparison to baseline (0.47±0.18 and 0.51±0.18 mm, respectively) (both P<0.001). The increase in axial length at 1 week relative to 24 months was statistically significant (0.04±0.06 mm; P=0.006). Anterior chamber depth did not change significantly over time (P=0.31). Significant differences were found between 24 months and 1 week relative to baseline and between 1-week and 24-month visits in mean corneal power (-1.68±0.80, -0.44±0.32, and 1.23±0.70 D, respectively) (all P≤0.001). Refractive change at 1 week in comparison to 24 months strongly correlated with changes in corneal power (r=-0.88; P<0.001) but not with axial length changes (r=-0.09; P=0.66). Corneal shape changed significantly between the baseline and 1-week visits (0.15±0.10 D; P<0.001). Corneal shape changed from a prolate to a more oblate corneal shape at the 24-month and 1-week visits in comparison to baseline (both P≤0.02) but did not change significantly between 24 months and 1 week (P=0.06). CONCLUSIONS: The effects of long-term OK on ocular biometry and refraction are still present after 1-week discontinuation of lens wear. Refractive change after discontinuation of long-term OK is primarily attributed to the recovery of corneal shape and not to an increase in the axial length.
OpenAlex reports 26 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
OBJECTIVE: To assess refractive and biometric changes 1 week after discontinuation of lens wear in subjects who had been wearing orthokeratology (OK) contact lenses for 2 years. METHODS: Twenty-nine subjects aged 6 to 12 years and with myopia of -0.75 to -4.00 diopters (D) and astigmatism of ≤1.00 D participated in the study. Measurements of axial length and anterior chamber depth (Zeiss IOLMaster), corneal power and shape, and cycloplegic refraction were taken 1 week after discontinuation and compared with those at baseline and after 24 months of lens wear. RESULTS: A hyperopic shift was found at 24 months relative to baseline in spherical equivalent refractive error (+1.86±1.01 D), followed by a myopic shift at 1 week relative to 24 months (-1.93±0.92 D) (both P<0.001). Longer axial lengths were found at 24 months and 1 week in comparison to baseline (0.47±0.18 and 0.51±0.18 mm, respectively) (both P<0.001). The increase in axial length at 1 week relative to 24 months was statistically significant (0.04±0.06 mm; P=0.006). Anterior chamber depth did not change significantly over time (P=0.31). Significant differences were found between 24 months and 1 week relative to baseline and between 1-week and 24-month visits in mean corneal power (-1.68±0.80, -0.44±0.32, and 1.23±0.70 D, respectively) (all P≤0.001). Refractive change at 1 week in comparison to 24 months strongly correlated with changes in corneal power (r=-0.88; P<0.001) but not with axial length changes (r=-0.09; P=0.66). Corneal shape changed significantly between the baseline and 1-week visits (0.15±0.10 D; P<0.001). Corneal shape changed from a prolate to a more oblate corneal shape at the 24-month and 1-week visits in comparison to baseline (both P≤0.02) but did not change significantly between 24 months and 1 week (P=0.06). CONCLUSIONS: The effects of long-term OK on ocular biometry and refraction are still present after 1-week discontinuation of lens wear. Refractive change after discontinuation of long-term OK is primarily attributed to the recovery of corneal shape and not to an increase in the axial length.
Key concepts: Orthokeratology, Dioptre, Discontinuation, Medicine, Ophthalmology, Refractive error, Astigmatism, Emmetropia