1996Rapid Communications in Mass SpectrometryRequires access

An External Source 7 T Fourier Transform Ion Cyclotron Resonance Mass Spectrometer with Electrostatic Ion Guide

Forest M. White, Jarrod A. Marto, Alan G. Marshall

Open publisher page 18 citations

Abstract

An external source 7 T Fourier transform ion cyclotron resonance (FTICR) mass spectrometer offers three main novel features. First, a 9-way ion-source cross allows for mounting of up to three ionization sources simultaneously, thereby minimizing 'downtime' for changing ion sources. Second, an electrostatic (wire-in-cylinder) ion guide transports the ions approximately 1.5 m from the ion source to the ion trap for mass analysis, through a large magnetic field gradient. Third, the system operates from a modular data system described elsewhere in this issue. Luteinizing hormone-releasing hormone (LH-RH) matrix-assisted laser desorption/ionization (MALDI) FTICR positive-ion mass spectra exhibit signal-to-noise ratio greater than 1000:1 and mass resolving power, m/delta m 50% > 100,000. Laser-induced fragmentation of bradykinin demonstrates the ability of the ion guide to transmit both molecular and fragment ions simultaneously. Ultra-high resolution (average resolving power approximately 400,000) was achieved for poly(ethylene glycol) of specified number-average molecular weight, Mn approximately 3400. Future installation of an electrospray source to the ion-source cross should allow for better characterization of the performance of the ion guide.

About this research paper

What this paper is about

An external source 7 T Fourier transform ion cyclotron resonance (FTICR) mass spectrometer offers three main novel features. First, a 9-way ion-source cross allows for mounting of up to three ionization sources simultaneously, thereby minimizing 'downtime' for changing ion sources. Second, an electrostatic (wire-in-cylinder) ion guide transports the ions approximately 1.5 m from the ion source to the ion trap for mass analysis, through a large magnetic field gradient. Third, the system operates from a modular data system described elsewhere in this issue. Luteinizing hormone-releasing hormone (LH-RH) matrix-assisted laser desorption/ionization (MALDI) FTICR positive-ion mass spectra exhibit signal-to-noise ratio greater than 1000:1 and mass resolving power, m/delta m 50% > 100,000. Laser-induced fragmentation of bradykinin demonstrates the ability of the ion guide to transmit both molecular and fragment ions simultaneously. Ultra-high resolution (average resolving power approximately 400,000) was achieved for poly(ethylene glycol) of specified number-average molecular weight, Mn approximately 3400. Future installation of an electrospray source to the ion-source cross should allow for better characterization of the performance of the ion guide.

Why it matters

OpenAlex reports 18 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

An external source 7 T Fourier transform ion cyclotron resonance (FTICR) mass spectrometer offers three main novel features. First, a 9-way ion-source cross allows for mounting of up to three ionization sources simultaneously, thereby minimizing 'downtime' for changing ion sources. Second, an electrostatic (wire-in-cylinder) ion guide transports the ions approximately 1.5 m from the ion source to the ion trap for mass analysis, through a large magnetic field gradient. Third, the system operates from a modular data system described elsewhere in this issue. Luteinizing hormone-releasing hormone (LH-RH) matrix-assisted laser desorption/ionization (MALDI) FTICR positive-ion mass spectra exhibit signal-to-noise ratio greater than 1000:1 and mass resolving power, m/delta m 50% > 100,000. Laser-induced fragmentation of bradykinin demonstrates the ability of the ion guide to transmit both molecular and fragment ions simultaneously. Ultra-high resolution (average resolving power approximately 400,000) was achieved for poly(ethylene glycol) of specified number-average molecular weight, Mn approximately 3400. Future installation of an electrospray source to the ion-source cross should allow for better characterization of the performance of the ion guide.

Key concepts: Fourier transform ion cyclotron resonance, Ion source, Chemistry, Ion cyclotron resonance, Reflectron, Mass spectrometry, Ion, Analytical Chemistry (journal)

Related papers

Back to paper searchBrowse research topicsOriginal source
An External Source 7 T Fourier Transform Ion Cyclotron Resonance Mass Spectrometer with Electrostatic Ion Guide — Research Paper | ScholarLens