Efficient injection of low‐mass ions into high magnetic field Fourier transform ion cyclotron resonance mass spectrometers

Behrooz Zekavat, Jan E. Szulejko, David Labrecque, Abayomi D. Olaitan, Touradj Solouki

Open publisher page 8 citations

Abstract

RATIONALE: Low-mass cut-off restrictions for injecting ions from external ion sources into high magnetic fields impose limitations for wide mass range analyses with Fourier transform ion cyclotron resonance (FTICR) instruments. Radio-frequency (RF)-only quadrupole ion guides (QIGs) with higher frequencies can be used to overcome low-mass cut-off in FTICR instruments. METHODS: RF signals (1.0 MHz to 10.0 MHz) were applied to QIGs to transfer externally generated ions from either electron ionization (EI) or electrospray ionization (ESI) sources into ICR cells of 9.4 T FTICR mass spectrometers. Efficiencies of QIGs were evaluated using externally generated ions from: EI of acetone, air, and perfluorotributylamine mixture, EI of gas chromatography (GC)-separated components of a standard sample mixture, and ESI of complex mixtures such as petroleum and fulvic acid samples. RESULTS: We were able to transfer ions with m/z as low as 26 from an external EI source into the ICR cell of a 9.4 T FTICR mass spectrometer and extend the operational low-mass range for ESI-FTICR analyses. High mass resolving power and mass measurement accuracy of GC/FTICR mass spectrometry were utilized to discriminate between oxygenated and non-oxygenated compounds in a 'Grob' sample. Ion losses based on SIMION ion trajectory predictions were consistent with experimental findings. CONCLUSIONS: We demonstrated that the use of high-frequency QIGs can extend the operational lower m/z range for both external EI- and ESI-FTICR mass spectrometers. By considering both ICR and Mathieu equations of motions to describe ion trajectories, theoretical ion ejection thresholds (consistent with our experimental findings) could be predicted.

About this research paper

What this paper is about

RATIONALE: Low-mass cut-off restrictions for injecting ions from external ion sources into high magnetic fields impose limitations for wide mass range analyses with Fourier transform ion cyclotron resonance (FTICR) instruments. Radio-frequency (RF)-only quadrupole ion guides (QIGs) with higher frequencies can be used to overcome low-mass cut-off in FTICR instruments. METHODS: RF signals (1.0 MHz to 10.0 MHz) were applied to QIGs to transfer externally generated ions from either electron ionization (EI) or electrospray ionization (ESI) sources into ICR cells of 9.4 T FTICR mass spectrometers. Efficiencies of QIGs were evaluated using externally generated ions from: EI of acetone, air, and perfluorotributylamine mixture, EI of gas chromatography (GC)-separated components of a standard sample mixture, and ESI of complex mixtures such as petroleum and fulvic acid samples. RESULTS: We were able to transfer ions with m/z as low as 26 from an external EI source into the ICR cell of a 9.4 T FTICR mass spectrometer and extend the operational low-mass range for ESI-FTICR analyses. High mass resolving power and mass measurement accuracy of GC/FTICR mass spectrometry were utilized to discriminate between oxygenated and non-oxygenated compounds in a 'Grob' sample. Ion losses based on SIMION ion trajectory predictions were consistent with experimental findings. CONCLUSIONS: We demonstrated that the use of high-frequency QIGs can extend the operational lower m/z range for both external EI- and ESI-FTICR mass spectrometers. By considering both ICR and Mathieu equations of motions to describe ion trajectories, theoretical ion ejection thresholds (consistent with our experimental findings) could be predicted.

Why it matters

OpenAlex reports 8 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

RATIONALE: Low-mass cut-off restrictions for injecting ions from external ion sources into high magnetic fields impose limitations for wide mass range analyses with Fourier transform ion cyclotron resonance (FTICR) instruments. Radio-frequency (RF)-only quadrupole ion guides (QIGs) with higher frequencies can be used to overcome low-mass cut-off in FTICR instruments. METHODS: RF signals (1.0 MHz to 10.0 MHz) were applied to QIGs to transfer externally generated ions from either electron ionization (EI) or electrospray ionization (ESI) sources into ICR cells of 9.4 T FTICR mass spectrometers. Efficiencies of QIGs were evaluated using externally generated ions from: EI of acetone, air, and perfluorotributylamine mixture, EI of gas chromatography (GC)-separated components of a standard sample mixture, and ESI of complex mixtures such as petroleum and fulvic acid samples. RESULTS: We were able to transfer ions with m/z as low as 26 from an external EI source into the ICR cell of a 9.4 T FTICR mass spectrometer and extend the operational low-mass range for ESI-FTICR analyses. High mass resolving power and mass measurement accuracy of GC/FTICR mass spectrometry were utilized to discriminate between oxygenated and non-oxygenated compounds in a 'Grob' sample. Ion losses based on SIMION ion trajectory predictions were consistent with experimental findings. CONCLUSIONS: We demonstrated that the use of high-frequency QIGs can extend the operational lower m/z range for both external EI- and ESI-FTICR mass spectrometers. By considering both ICR and Mathieu equations of motions to describe ion trajectories, theoretical ion ejection thresholds (consistent with our experimental findings) could be predicted.

Key concepts: Fourier transform ion cyclotron resonance, Chemistry, Ion cyclotron resonance, Mass spectrometry, Ion, Selected ion monitoring, Cyclotron resonance, Cyclotron

Related papers

Back to paper searchBrowse research topicsOriginal source
Efficient injection of low‐mass ions into high magnetic field Fourier transform ion cyclotron resonance mass spectrometers — Research Paper | ScholarLens