1994Anesthesia & AnalgesiaRequires access

Syringe Pumps for Infusion of Vasoactive Drugs

G. Alec Rooke, Andrew Bowdle

Open publisher page 58 citations

Abstract

Syringe pumps for vasoactive infusions have the advantages of small size and weight, portability, and low cost of the disposable components. However, limited syringe capacity necessitates the use of high drug concentrations, and the accidental delivery of even a small volume of infusate could seriously alter the patient's hemodynamics. To determine the circumstances under which drug delivery might be delayed, or inadvertent boluses could be delivered into the manifold, two brands of commercially available clinical syringe pumps were connected to a stopcock manifold via small-bore tubing and a series of tests were performed. When the syringe pumps were operated at 3 mL/h against a closed stopcock, the pumps' occlusion alarms did not sound for 18-22 min, and when the stopcock subsequently was opened, 0.6-0.9 mL of infusate was delivered as a bolus. Elevating the syringe pump by 120 cm resulted in the delivery of up to 0.5 mL of infusate with the pump turned off. When a syringe pump operating at 6 mL/h was turned off, typically an additional 0.05 mL was delivered during the ensuing 2-3 min. Depending upon the method used to flush the tubing prior to use, delays in drug delivery of 2-3 min occurred at an infusion rate of 3 mL/h. These observations emphasize the need for careful equipment setup and proper use of the manifold stopcocks to avoid unintended drug administration or delay in drug administration.

About this research paper

What this paper is about

Syringe pumps for vasoactive infusions have the advantages of small size and weight, portability, and low cost of the disposable components. However, limited syringe capacity necessitates the use of high drug concentrations, and the accidental delivery of even a small volume of infusate could seriously alter the patient's hemodynamics. To determine the circumstances under which drug delivery might be delayed, or inadvertent boluses could be delivered into the manifold, two brands of commercially available clinical syringe pumps were connected to a stopcock manifold via small-bore tubing and a series of tests were performed. When the syringe pumps were operated at 3 mL/h against a closed stopcock, the pumps' occlusion alarms did not sound for 18-22 min, and when the stopcock subsequently was opened, 0.6-0.9 mL of infusate was delivered as a bolus. Elevating the syringe pump by 120 cm resulted in the delivery of up to 0.5 mL of infusate with the pump turned off. When a syringe pump operating at 6 mL/h was turned off, typically an additional 0.05 mL was delivered during the ensuing 2-3 min. Depending upon the method used to flush the tubing prior to use, delays in drug delivery of 2-3 min occurred at an infusion rate of 3 mL/h. These observations emphasize the need for careful equipment setup and proper use of the manifold stopcocks to avoid unintended drug administration or delay in drug administration.

Why it matters

OpenAlex reports 58 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Syringe pumps for vasoactive infusions have the advantages of small size and weight, portability, and low cost of the disposable components. However, limited syringe capacity necessitates the use of high drug concentrations, and the accidental delivery of even a small volume of infusate could seriously alter the patient's hemodynamics. To determine the circumstances under which drug delivery might be delayed, or inadvertent boluses could be delivered into the manifold, two brands of commercially available clinical syringe pumps were connected to a stopcock manifold via small-bore tubing and a series of tests were performed. When the syringe pumps were operated at 3 mL/h against a closed stopcock, the pumps' occlusion alarms did not sound for 18-22 min, and when the stopcock subsequently was opened, 0.6-0.9 mL of infusate was delivered as a bolus. Elevating the syringe pump by 120 cm resulted in the delivery of up to 0.5 mL of infusate with the pump turned off. When a syringe pump operating at 6 mL/h was turned off, typically an additional 0.05 mL was delivered during the ensuing 2-3 min. Depending upon the method used to flush the tubing prior to use, delays in drug delivery of 2-3 min occurred at an infusion rate of 3 mL/h. These observations emphasize the need for careful equipment setup and proper use of the manifold stopcocks to avoid unintended drug administration or delay in drug administration.

Key concepts: Syringe, Medicine, Syringe driver, Vasoactive, Infusion pump, Anesthesia, Bolus (digestion), Drug administration

Related papers

Back to paper searchBrowse research topicsOriginal source
Syringe Pumps for Infusion of Vasoactive Drugs — Research Paper | ScholarLens