Abstract

OBJECTIVE: To determine the effectiveness of the malleus to oval window wire-piston revision stapes surgery technique. STUDY DESIGN: A retrospective analysis of 243 stapes procedures performed by the senior author over a 10-year period identified 15 revisions. Five patients underwent a malleus to oval window wire-piston technique. All patients were followed for at least 6 months. The surgical outcome including audiologic data and complications are noted. METHODS: Stapes surgery was performed on an ambulatory basis by way of a transcanal approach under local anesthesia with monitored sedation by the same surgeon using a laser technique and a stapes wire-piston prosthesis. RESULTS: Among revision stapes procedures, there was no significant difference in the air-bone gap closure or complication rate between the incus to oval window and the malleus to oval window techniques. The average preoperative air-bone gap in all revisions was 32 dB, whereas the mean postoperative gap was 10 dB hearing loss. CONCLUSIONS: In experienced hands, revision stapes surgery using the malleus to oval window stapes wire-piston prosthesis is safe and effective.

About this research paper

What this paper is about

OBJECTIVE: To determine the effectiveness of the malleus to oval window wire-piston revision stapes surgery technique. STUDY DESIGN: A retrospective analysis of 243 stapes procedures performed by the senior author over a 10-year period identified 15 revisions. Five patients underwent a malleus to oval window wire-piston technique. All patients were followed for at least 6 months. The surgical outcome including audiologic data and complications are noted. METHODS: Stapes surgery was performed on an ambulatory basis by way of a transcanal approach under local anesthesia with monitored sedation by the same surgeon using a laser technique and a stapes wire-piston prosthesis. RESULTS: Among revision stapes procedures, there was no significant difference in the air-bone gap closure or complication rate between the incus to oval window and the malleus to oval window techniques. The average preoperative air-bone gap in all revisions was 32 dB, whereas the mean postoperative gap was 10 dB hearing loss. CONCLUSIONS: In experienced hands, revision stapes surgery using the malleus to oval window stapes wire-piston prosthesis is safe and effective.

Why it matters

OpenAlex reports 22 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

OBJECTIVE: To determine the effectiveness of the malleus to oval window wire-piston revision stapes surgery technique. STUDY DESIGN: A retrospective analysis of 243 stapes procedures performed by the senior author over a 10-year period identified 15 revisions. Five patients underwent a malleus to oval window wire-piston technique. All patients were followed for at least 6 months. The surgical outcome including audiologic data and complications are noted. METHODS: Stapes surgery was performed on an ambulatory basis by way of a transcanal approach under local anesthesia with monitored sedation by the same surgeon using a laser technique and a stapes wire-piston prosthesis. RESULTS: Among revision stapes procedures, there was no significant difference in the air-bone gap closure or complication rate between the incus to oval window and the malleus to oval window techniques. The average preoperative air-bone gap in all revisions was 32 dB, whereas the mean postoperative gap was 10 dB hearing loss. CONCLUSIONS: In experienced hands, revision stapes surgery using the malleus to oval window stapes wire-piston prosthesis is safe and effective.

Key concepts: Stapes, Malleus, Oval window, Incus, Medicine, Surgery, Stapes surgery, Prosthesis

Related papers

Back to paper searchBrowse research topicsOriginal source
Revision Stapes Surgery: The Malleus to Oval Window Wire‐Piston Technique — Research Paper | ScholarLens