1995Nippon Jibiinkoka Gakkai KaihoOpen access

THREE-DIMENSIONAL CT OF THE OSSICLES OF THE MIDDLE EAR

Hideo Edamatsu, Koichi Yamashita

Open full text 1 citations

Abstract

This study was performed to evaluate the usefulness and limitations of three-dimensional (3-D) imaging of the ossicular chain in the middle ear by high speed helical CT. One dissected human temporal bone, five normal ears, and twelve diseased ears (trauma, ossicular anomaly, cholesteatoma, chronic otitis media) were scanned in 1.0mm slices and reconstructed at a thickness of 0.2-0.5mm. All 3-D CT specimens can be observed in any plane and from any direction. Ossicular 3-D CT temporal bone images were reconstructed as if the malleus, incus and stapes were being observed under a microscope. No defect in the ossicles or their joints was seen in the images. The entire structure of the stapes could not be represented by conventional two-dimensional CT, but the 3-D CT in our study showed the head, crus and foot plate of the stapes in detail. Ossicular 3-D CT images of normal ears yielded the same findings as those recorded in the temporal bone. Preoperative diagnostic findings of ossicles in diseased ears were very useful. 3-D CT was diagnostic and its accuracy was confirmed by surgical observations, especially in ossicular anomalies. 3-D CT was also an important method of postoperative evaluation of ossicular reconstruction, i.e. TORP and PORP. It could represent the anatomical relation between prosthesis and the oval window. Postoperative hearing improvement can be compared with 3-D CT findings. High-speed helical CT can scan an object more quickly and clearly than conventional CT, and its biological damage in humans is less than that of other methods.

Open-access reader

About this research paper

What this paper is about

This study was performed to evaluate the usefulness and limitations of three-dimensional (3-D) imaging of the ossicular chain in the middle ear by high speed helical CT. One dissected human temporal bone, five normal ears, and twelve diseased ears (trauma, ossicular anomaly, cholesteatoma, chronic otitis media) were scanned in 1.0mm slices and reconstructed at a thickness of 0.2-0.5mm. All 3-D CT specimens can be observed in any plane and from any direction. Ossicular 3-D CT temporal bone images were reconstructed as if the malleus, incus and stapes were being observed under a microscope. No defect in the ossicles or their joints was seen in the images. The entire structure of the stapes could not be represented by conventional two-dimensional CT, but the 3-D CT in our study showed the head, crus and foot plate of the stapes in detail. Ossicular 3-D CT images of normal ears yielded the same findings as those recorded in the temporal bone. Preoperative diagnostic findings of ossicles in diseased ears were very useful. 3-D CT was diagnostic and its accuracy was confirmed by surgical observations, especially in ossicular anomalies. 3-D CT was also an important method of postoperative evaluation of ossicular reconstruction, i.e. TORP and PORP. It could represent the anatomical relation between prosthesis and the oval window. Postoperative hearing improvement can be compared with 3-D CT findings. High-speed helical CT can scan an object more quickly and clearly than conventional CT, and its biological damage in humans is less than that of other methods.

Why it matters

OpenAlex reports 1 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

This study was performed to evaluate the usefulness and limitations of three-dimensional (3-D) imaging of the ossicular chain in the middle ear by high speed helical CT. One dissected human temporal bone, five normal ears, and twelve diseased ears (trauma, ossicular anomaly, cholesteatoma, chronic otitis media) were scanned in 1.0mm slices and reconstructed at a thickness of 0.2-0.5mm. All 3-D CT specimens can be observed in any plane and from any direction. Ossicular 3-D CT temporal bone images were reconstructed as if the malleus, incus and stapes were being observed under a microscope. No defect in the ossicles or their joints was seen in the images. The entire structure of the stapes could not be represented by conventional two-dimensional CT, but the 3-D CT in our study showed the head, crus and foot plate of the stapes in detail. Ossicular 3-D CT images of normal ears yielded the same findings as those recorded in the temporal bone. Preoperative diagnostic findings of ossicles in diseased ears were very useful. 3-D CT was diagnostic and its accuracy was confirmed by surgical observations, especially in ossicular anomalies. 3-D CT was also an important method of postoperative evaluation of ossicular reconstruction, i.e. TORP and PORP. It could represent the anatomical relation between prosthesis and the oval window. Postoperative hearing improvement can be compared with 3-D CT findings. High-speed helical CT can scan an object more quickly and clearly than conventional CT, and its biological damage in humans is less than that of other methods.

Key concepts: Incus, Ossicles, Stapes, Malleus, Middle ear, Temporal bone, Cholesteatoma, Medicine

Related papers

Back to paper searchBrowse research topicsOriginal source
THREE-DIMENSIONAL CT OF THE OSSICLES OF THE MIDDLE EAR — Research Paper | ScholarLens