2010Structures Congress 2010Requires access

A Case Study of Bridge Strengthening through the Use of Post-Installed Shear Connectors

Gunup Kwon, Michael D. Engelhardt, Richard E. Klingner

Open publisher page 4 citations

Abstract

This paper presents a summary of a project where post-installed shear connectors were used to strengthen an older non-composite steel girder bridge located near the town of Hondo, Texas. The use of post-installed shear connectors permits the development of composite action between the existing steel girders and the existing reinforced concrete deck, thereby increasing the flexural strength of the girders. The very good fatigue strength of these post-installed shear connectors enabled the use of partial composite design. As a result, far fewer post-installed shear connectors were needed than if conventional welded studs were used. For this bridge, the addition of post-installed shear connectors resulted in approximately a 65-percent increase in the Inventory and Operating level load ratings. Also presented in this paper are load test results which were conducted to verify composite action at the steel-concrete interface after the retrofit and compare the structural behavior of the bridge before and after the retrofit.

About this research paper

What this paper is about

This paper presents a summary of a project where post-installed shear connectors were used to strengthen an older non-composite steel girder bridge located near the town of Hondo, Texas. The use of post-installed shear connectors permits the development of composite action between the existing steel girders and the existing reinforced concrete deck, thereby increasing the flexural strength of the girders. The very good fatigue strength of these post-installed shear connectors enabled the use of partial composite design. As a result, far fewer post-installed shear connectors were needed than if conventional welded studs were used. For this bridge, the addition of post-installed shear connectors resulted in approximately a 65-percent increase in the Inventory and Operating level load ratings. Also presented in this paper are load test results which were conducted to verify composite action at the steel-concrete interface after the retrofit and compare the structural behavior of the bridge before and after the retrofit.

Why it matters

OpenAlex reports 4 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

This paper presents a summary of a project where post-installed shear connectors were used to strengthen an older non-composite steel girder bridge located near the town of Hondo, Texas. The use of post-installed shear connectors permits the development of composite action between the existing steel girders and the existing reinforced concrete deck, thereby increasing the flexural strength of the girders. The very good fatigue strength of these post-installed shear connectors enabled the use of partial composite design. As a result, far fewer post-installed shear connectors were needed than if conventional welded studs were used. For this bridge, the addition of post-installed shear connectors resulted in approximately a 65-percent increase in the Inventory and Operating level load ratings. Also presented in this paper are load test results which were conducted to verify composite action at the steel-concrete interface after the retrofit and compare the structural behavior of the bridge before and after the retrofit.

Key concepts: Girder, Structural engineering, Deck, Bridge (graph theory), Shear (geology), Composite number, Bridge deck, Engineering

Related papers

Back to paper searchBrowse research topicsOriginal source
A Case Study of Bridge Strengthening through the Use of Post-Installed Shear Connectors — Research Paper | ScholarLens