2001•Analytical ChemistryRequires access

Ultrafast Sodium Dodecyl Sulfate Micellar Electrokinetic Chromatography with Very Acidic Running Buffers

Miguel Ángel Rodríguez‐Delgado, F. García-Montelongo, Alejandro Cifuentes

Open publisher page 19 citations

Abstract

A new micellar electrokinetic chromatography (MEKC) procedure has been developed that allows the use of the anionic surfactant sodium dodecyl sulfate (SDS) together with separation buffers at pHs as low as 1. The technique is based on the employment of a high molecular weight polyethylenimine (PEI)-coated capillary that provides strong cathodal electroosmotic flows at acidic pHs when SDS is added to the running buffer. The procedure is easy to implement since the capillary coating is done by just flushing a PEI aqueous solution through the capillary and the subsequent steps are the same as those for any MEKC protocol. Moreover, the coating renewal provides reproducible separations between injections (migration time RSD values lower than 1.82 and 3.44% were obtained for the same day and three different days, respectively). The good possibilities of this system are demonstrated by showing the separation of a group of eight polyphenolic compounds within a separation time shorter than 2 min. This procedure allows one to extend the optimization of SDS-MEKC separations to the very acidic pH range too.

About this research paper

What this paper is about

A new micellar electrokinetic chromatography (MEKC) procedure has been developed that allows the use of the anionic surfactant sodium dodecyl sulfate (SDS) together with separation buffers at pHs as low as 1. The technique is based on the employment of a high molecular weight polyethylenimine (PEI)-coated capillary that provides strong cathodal electroosmotic flows at acidic pHs when SDS is added to the running buffer. The procedure is easy to implement since the capillary coating is done by just flushing a PEI aqueous solution through the capillary and the subsequent steps are the same as those for any MEKC protocol. Moreover, the coating renewal provides reproducible separations between injections (migration time RSD values lower than 1.82 and 3.44% were obtained for the same day and three different days, respectively). The good possibilities of this system are demonstrated by showing the separation of a group of eight polyphenolic compounds within a separation time shorter than 2 min. This procedure allows one to extend the optimization of SDS-MEKC separations to the very acidic pH range too.

Why it matters

OpenAlex reports 19 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A new micellar electrokinetic chromatography (MEKC) procedure has been developed that allows the use of the anionic surfactant sodium dodecyl sulfate (SDS) together with separation buffers at pHs as low as 1. The technique is based on the employment of a high molecular weight polyethylenimine (PEI)-coated capillary that provides strong cathodal electroosmotic flows at acidic pHs when SDS is added to the running buffer. The procedure is easy to implement since the capillary coating is done by just flushing a PEI aqueous solution through the capillary and the subsequent steps are the same as those for any MEKC protocol. Moreover, the coating renewal provides reproducible separations between injections (migration time RSD values lower than 1.82 and 3.44% were obtained for the same day and three different days, respectively). The good possibilities of this system are demonstrated by showing the separation of a group of eight polyphenolic compounds within a separation time shorter than 2 min. This procedure allows one to extend the optimization of SDS-MEKC separations to the very acidic pH range too.

Key concepts: Micellar electrokinetic chromatography, Chemistry, Sodium dodecyl sulfate, Chromatography, Electrokinetic phenomena, Pulmonary surfactant, Polyethylenimine, Capillary electrophoresis

Related papers

Back to paper searchBrowse research topicsOriginal source
Ultrafast Sodium Dodecyl Sulfate Micellar Electrokinetic Chromatography with Very Acidic Running Buffers — Research Paper | ScholarLens