2001•Radiation Protection DosimetryRequires access

Fit of First Order Thermoluminescence Glow Peaks using the Weibull Distribution Function

Vasilis Pagonis, S. Mian, G. Kitis

Open publisher page 32 citations

Abstract

A new thermoluminescence glow curve deconvolution (GCD) function is introduced which accurately describes first order thermoluminescence (TL) curves. The new GCD function is found to be accurate for first order TL peaks with a wide variety of the values of the TL kinetic parameters E and s. The 3-parameter Weibull probability function is used with the function variables being the maximum peak intensity (Im), the temperature of the maximum peak intensity (Tm) and the Weibull width parameter b. An analytical expression is derived from which the activation energy E can be calculated as a function of Tm and the Weibull width parameter b. The accuracy of the Weibull fit was tested using the ten reference glow curves of the GLOCANIN intercomparison program and the Weibull distribution was found to be highly effective in describing both single and complex TL glow curves. The goodness of fit of the Weibull function is described by the Figure of Merit (FOM) which is found to be of comparable accuracy to the best FOM values of the GLOCANIN program. The FOM values are also comparable to the FOM values obtained using the recently published GCD functions of Kitis et al. It is found that the TL kinetic analysis of complex first-order TL glow curves can be performed with high accuracy and speed by using commercially available software packages.

About this research paper

What this paper is about

A new thermoluminescence glow curve deconvolution (GCD) function is introduced which accurately describes first order thermoluminescence (TL) curves. The new GCD function is found to be accurate for first order TL peaks with a wide variety of the values of the TL kinetic parameters E and s. The 3-parameter Weibull probability function is used with the function variables being the maximum peak intensity (Im), the temperature of the maximum peak intensity (Tm) and the Weibull width parameter b. An analytical expression is derived from which the activation energy E can be calculated as a function of Tm and the Weibull width parameter b. The accuracy of the Weibull fit was tested using the ten reference glow curves of the GLOCANIN intercomparison program and the Weibull distribution was found to be highly effective in describing both single and complex TL glow curves. The goodness of fit of the Weibull function is described by the Figure of Merit (FOM) which is found to be of comparable accuracy to the best FOM values of the GLOCANIN program. The FOM values are also comparable to the FOM values obtained using the recently published GCD functions of Kitis et al. It is found that the TL kinetic analysis of complex first-order TL glow curves can be performed with high accuracy and speed by using commercially available software packages.

Why it matters

OpenAlex reports 32 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A new thermoluminescence glow curve deconvolution (GCD) function is introduced which accurately describes first order thermoluminescence (TL) curves. The new GCD function is found to be accurate for first order TL peaks with a wide variety of the values of the TL kinetic parameters E and s. The 3-parameter Weibull probability function is used with the function variables being the maximum peak intensity (Im), the temperature of the maximum peak intensity (Tm) and the Weibull width parameter b. An analytical expression is derived from which the activation energy E can be calculated as a function of Tm and the Weibull width parameter b. The accuracy of the Weibull fit was tested using the ten reference glow curves of the GLOCANIN intercomparison program and the Weibull distribution was found to be highly effective in describing both single and complex TL glow curves. The goodness of fit of the Weibull function is described by the Figure of Merit (FOM) which is found to be of comparable accuracy to the best FOM values of the GLOCANIN program. The FOM values are also comparable to the FOM values obtained using the recently published GCD functions of Kitis et al. It is found that the TL kinetic analysis of complex first-order TL glow curves can be performed with high accuracy and speed by using commercially available software packages.

Key concepts: Weibull distribution, Thermoluminescence, Shape parameter, Goodness of fit, Statistics, Deconvolution, Mathematics, Materials science

Related papers

Back to paper searchBrowse research topicsOriginal source
Fit of First Order Thermoluminescence Glow Peaks using the Weibull Distribution Function — Research Paper | ScholarLens