2008•Open ChemistryOpen access

Determination of phenolic acids by capillary zone electrophoresis and HPLC

František Kvasnička, Jana Čopı́ková, Rudolf Ševčík, Jana Krátká, Andriy Synytsya, M. Voldřich

Open full text 26 citations

Abstract

Abstract Selected phenolic acids are determined by capillary zone electrophoresis and HPLC, each using UV detection. The optimised CZE background electrolyte contained 50 mM acetic acid, 95 mM 6-aminocaproic acid, 0.1% polyacrylamide, 1% polyvinylpyrrolidone, and 10% methanol. Twelve phenolic acids (gallic, p-hydroxybenzoic, 3,4-dihydroxybenzoic, vanillic, syringic, o-coumaric, p-coumaric, caffeic, sinapic, ferulic, salicylic and chlorogenic) were separated within 10 minutes. Chromatographic separation of these phenolic acids was carried out on an Eclipse XBD C8 column using a mobile phase gradient (acetonitrile / methanol / water / 0.1% phosphoric acid); all were separated within 25 minutes. Electrophoretic and chromatographic determinations of ferulic and chlorogenic acids were compared on barley, malt, and potato samples. The methods’ characteristics were: linearity (1–20 mg ml and 0.2–4 mg ml−1), accuracy (recovery 94 ± 5% and 96 ± 4%), intra-assay repeatability (4.1% and 3.5%), and detection limit (0.2 and 0.02 mg ml−1).

Open-access reader

About this research paper

What this paper is about

Abstract Selected phenolic acids are determined by capillary zone electrophoresis and HPLC, each using UV detection. The optimised CZE background electrolyte contained 50 mM acetic acid, 95 mM 6-aminocaproic acid, 0.1% polyacrylamide, 1% polyvinylpyrrolidone, and 10% methanol. Twelve phenolic acids (gallic, p-hydroxybenzoic, 3,4-dihydroxybenzoic, vanillic, syringic, o-coumaric, p-coumaric, caffeic, sinapic, ferulic, salicylic and chlorogenic) were separated within 10 minutes. Chromatographic separation of these phenolic acids was carried out on an Eclipse XBD C8 column using a mobile phase gradient (acetonitrile / methanol / water / 0.1% phosphoric acid); all were separated within 25 minutes. Electrophoretic and chromatographic determinations of ferulic and chlorogenic acids were compared on barley, malt, and potato samples. The methods’ characteristics were: linearity (1–20 mg ml and 0.2–4 mg ml−1), accuracy (recovery 94 ± 5% and 96 ± 4%), intra-assay repeatability (4.1% and 3.5%), and detection limit (0.2 and 0.02 mg ml−1).

Why it matters

OpenAlex reports 26 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Abstract Selected phenolic acids are determined by capillary zone electrophoresis and HPLC, each using UV detection. The optimised CZE background electrolyte contained 50 mM acetic acid, 95 mM 6-aminocaproic acid, 0.1% polyacrylamide, 1% polyvinylpyrrolidone, and 10% methanol. Twelve phenolic acids (gallic, p-hydroxybenzoic, 3,4-dihydroxybenzoic, vanillic, syringic, o-coumaric, p-coumaric, caffeic, sinapic, ferulic, salicylic and chlorogenic) were separated within 10 minutes. Chromatographic separation of these phenolic acids was carried out on an Eclipse XBD C8 column using a mobile phase gradient (acetonitrile / methanol / water / 0.1% phosphoric acid); all were separated within 25 minutes. Electrophoretic and chromatographic determinations of ferulic and chlorogenic acids were compared on barley, malt, and potato samples. The methods’ characteristics were: linearity (1–20 mg ml and 0.2–4 mg ml−1), accuracy (recovery 94 ± 5% and 96 ± 4%), intra-assay repeatability (4.1% and 3.5%), and detection limit (0.2 and 0.02 mg ml−1).

Key concepts: Chromatography, Chemistry, Capillary electrophoresis, Chlorogenic acid, High-performance liquid chromatography, p-Coumaric acid, Detection limit, Ferulic acid

Related papers

Back to paper searchBrowse research topicsOriginal source
Determination of phenolic acids by capillary zone electrophoresis and HPLC — Research Paper | ScholarLens