2011Acta Oto-LaryngologicaRequires access

Correlation between caloric and ocular vestibular evoked myogenic potential test results

Chi-Hsuan Huang, Shou‐Jen Wang, Yi‐Ho Young

Open publisher page 33 citations

Abstract

CONCLUSION: The ocular vestibular evoked myogenic potential (o-VEMP) test results correlate significantly with caloric test results for patients with acoustic neuroma (AN), but not for patients with Meniere's disease (MD), indicating that the o-VEMP test may replace the caloric test for evaluating the vestibular nerve from which the AN arises. Conversely, the caloric, o-VEMP, and cervical VEMP (c-VEMP) tests should be performed to map lesion sites in the vestibular labyrinth. OBJECTIVE: This study performed caloric, o-VEMP, and c-VEMP tests on patients with central and peripheral vestibular disorders to investigate their relationships. METHODS: In all, 66 patients comprising 16 with unilateral AN and 50 with unilateral definite MD were enrolled. All patients underwent caloric, o-VEMP, and c-VEMP tests. RESULTS: In the AN group, the caloric test identified canal paresis and caloric areflexia in 10 ears, while the o-VEMP and c-VEMP tests identified abnormal (absent or delayed) responses in 12 and 11 ears, respectively. A significant correlation existed between caloric and o-VEMP test results, but not between caloric and c-VEMP test results, or between o-VEMP and c-VEMP test results. For the MD group, abnormal caloric, o-VEMP, and c-VEMP test results were obtained for 24%, 44%, and 38% of hydropic ears, respectively. No correlation existed between any two test results.

About this research paper

What this paper is about

CONCLUSION: The ocular vestibular evoked myogenic potential (o-VEMP) test results correlate significantly with caloric test results for patients with acoustic neuroma (AN), but not for patients with Meniere's disease (MD), indicating that the o-VEMP test may replace the caloric test for evaluating the vestibular nerve from which the AN arises. Conversely, the caloric, o-VEMP, and cervical VEMP (c-VEMP) tests should be performed to map lesion sites in the vestibular labyrinth. OBJECTIVE: This study performed caloric, o-VEMP, and c-VEMP tests on patients with central and peripheral vestibular disorders to investigate their relationships. METHODS: In all, 66 patients comprising 16 with unilateral AN and 50 with unilateral definite MD were enrolled. All patients underwent caloric, o-VEMP, and c-VEMP tests. RESULTS: In the AN group, the caloric test identified canal paresis and caloric areflexia in 10 ears, while the o-VEMP and c-VEMP tests identified abnormal (absent or delayed) responses in 12 and 11 ears, respectively. A significant correlation existed between caloric and o-VEMP test results, but not between caloric and c-VEMP test results, or between o-VEMP and c-VEMP test results. For the MD group, abnormal caloric, o-VEMP, and c-VEMP test results were obtained for 24%, 44%, and 38% of hydropic ears, respectively. No correlation existed between any two test results.

Why it matters

OpenAlex reports 33 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

CONCLUSION: The ocular vestibular evoked myogenic potential (o-VEMP) test results correlate significantly with caloric test results for patients with acoustic neuroma (AN), but not for patients with Meniere's disease (MD), indicating that the o-VEMP test may replace the caloric test for evaluating the vestibular nerve from which the AN arises. Conversely, the caloric, o-VEMP, and cervical VEMP (c-VEMP) tests should be performed to map lesion sites in the vestibular labyrinth. OBJECTIVE: This study performed caloric, o-VEMP, and c-VEMP tests on patients with central and peripheral vestibular disorders to investigate their relationships. METHODS: In all, 66 patients comprising 16 with unilateral AN and 50 with unilateral definite MD were enrolled. All patients underwent caloric, o-VEMP, and c-VEMP tests. RESULTS: In the AN group, the caloric test identified canal paresis and caloric areflexia in 10 ears, while the o-VEMP and c-VEMP tests identified abnormal (absent or delayed) responses in 12 and 11 ears, respectively. A significant correlation existed between caloric and o-VEMP test results, but not between caloric and c-VEMP test results, or between o-VEMP and c-VEMP test results. For the MD group, abnormal caloric, o-VEMP, and c-VEMP test results were obtained for 24%, 44%, and 38% of hydropic ears, respectively. No correlation existed between any two test results.

Key concepts: Vestibular evoked myogenic potential, Caloric theory, Audiology, Medicine, Vestibular nerve, Caloric test, Vestibular system, Meniere's disease

Related papers

Back to paper searchBrowse research topicsOriginal source
Correlation between caloric and ocular vestibular evoked myogenic potential test results — Research Paper | ScholarLens