2012•Journal of InstrumentationRequires access

Application of charge-injection devices for digital X-ray imaging using a planar gas-type X-ray detector

Kyung-Min Oh, Jae‐Gook Shin, M Yun, H Park, J Park, Sanghee Nam

Open publisher page 1 citations

Abstract

We have developed a planar gas-type detector, based on a charge injection device; this device can be used for digital X-ray imaging. Previously, in order to obtain X-ray images, a planar gas-type detector utilized a line-scanning module based on a one-dimensional readout system; however, that technology suffered from a limitation such as a long readout time, not suitable for a fluoroscopy or a moving imaging acquisition. In this study, a readout module based on charge-injection devices was used in conjunction with the planar gas-type detector to acquire signals and two-dimensional digital images. In the original design, two orthogonally cross-shaped top electrodes, called X address and Y address, played important roles in transferring and collecting the generated charges using electrical potential. During the optimization process, the shape of these top electrodes was modified into a honeycomb shape to increase the efficacy of charge collection. A mixture of gas and dielectric layers were selected to make an efficient gas-type detector for digital X-ray imaging. From the result, the electrical properties of the detector were investigated and the effectiveness of its geometrical design was proved. Measurements demonstrated the linearity of X-ray detection, and the successful movement and collection of charge using electrical potential. Thus, this modified planar gas-type detector and charge readout module using a charge-injection device made it possible to obtain two-dimensional images without using a scanning mode.

About this research paper

What this paper is about

We have developed a planar gas-type detector, based on a charge injection device; this device can be used for digital X-ray imaging. Previously, in order to obtain X-ray images, a planar gas-type detector utilized a line-scanning module based on a one-dimensional readout system; however, that technology suffered from a limitation such as a long readout time, not suitable for a fluoroscopy or a moving imaging acquisition. In this study, a readout module based on charge-injection devices was used in conjunction with the planar gas-type detector to acquire signals and two-dimensional digital images. In the original design, two orthogonally cross-shaped top electrodes, called X address and Y address, played important roles in transferring and collecting the generated charges using electrical potential. During the optimization process, the shape of these top electrodes was modified into a honeycomb shape to increase the efficacy of charge collection. A mixture of gas and dielectric layers were selected to make an efficient gas-type detector for digital X-ray imaging. From the result, the electrical properties of the detector were investigated and the effectiveness of its geometrical design was proved. Measurements demonstrated the linearity of X-ray detection, and the successful movement and collection of charge using electrical potential. Thus, this modified planar gas-type detector and charge readout module using a charge-injection device made it possible to obtain two-dimensional images without using a scanning mode.

Why it matters

OpenAlex reports 1 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

We have developed a planar gas-type detector, based on a charge injection device; this device can be used for digital X-ray imaging. Previously, in order to obtain X-ray images, a planar gas-type detector utilized a line-scanning module based on a one-dimensional readout system; however, that technology suffered from a limitation such as a long readout time, not suitable for a fluoroscopy or a moving imaging acquisition. In this study, a readout module based on charge-injection devices was used in conjunction with the planar gas-type detector to acquire signals and two-dimensional digital images. In the original design, two orthogonally cross-shaped top electrodes, called X address and Y address, played important roles in transferring and collecting the generated charges using electrical potential. During the optimization process, the shape of these top electrodes was modified into a honeycomb shape to increase the efficacy of charge collection. A mixture of gas and dielectric layers were selected to make an efficient gas-type detector for digital X-ray imaging. From the result, the electrical properties of the detector were investigated and the effectiveness of its geometrical design was proved. Measurements demonstrated the linearity of X-ray detection, and the successful movement and collection of charge using electrical potential. Thus, this modified planar gas-type detector and charge readout module using a charge-injection device made it possible to obtain two-dimensional images without using a scanning mode.

Key concepts: X-ray, X-ray detector, Planar, Detector, Materials science, Optoelectronics, Physics, Optics

Related papers

Back to paper searchBrowse research topicsOriginal source
Application of charge-injection devices for digital X-ray imaging using a planar gas-type X-ray detector — Research Paper | ScholarLens