2009Journal of Applied CrystallographyRequires access

A small/wide-angle X-ray scattering instrument for structural characterization of air–liquid interfaces, thin films and bulk specimens

U‐Ser Jeng, Chiu Hun Su, Chun‐Jen Su, Kuei-Fen Liao, Wei‐Tsung Chuang, Ying‐Huang Lai, Je‐Wei Chang, Yi‐Jiun Chen, Yu-Shan Huang, Ming-Tao Lee, Kuan-Li Yu, Jhih‐Min Lin, Din‐Goa Liu, Chia-Feng Chang, Chin-Yen Liu, Chien-Hung Chang, Keng S. Liang

Open publisher page 177 citations

Abstract

At the National Synchrotron Radiation Research Center, a small/wide-angle X-ray scattering (SAXS/WAXS) instrument has been installed at the BL23A beamline with a superconducting wiggler insertion device. This beamline is equipped with double Si(111) crystal and double Mo/B4C multilayer monochromators, and an Si-based plane mirror that can selectively deflect the beam downwards for grazing-incidence SAXS (GISAXS) studies of air–liquid or liquid–liquid interfaces. The SAXS/WAXS instrument, situated in an experimental hutch, comprises collimation, sample and post-sample stages. Pinholes and slits have been incorporated into the beam collimation system spanning a distance of ∼5 m. The sample stage can accommodate various sample geometries for air–liquid interfaces, thin films, and solution and solid samples. The post-sample section consists of a 1 m WAXS section with two linear gas detectors, a vacuum bellows (1–4 m), a two-beamstop system and the SAXS detector system, all situated on a motorized optical bench for motion in six degrees of freedom. In particular, the vacuum bellows of a large inner diameter (260 mm) provides continuous changes of the sample-to-detector distance under vacuum. Synchronized SAXS and WAXS measurements are realizedviaa data-acquisition protocol that can integrate the two linear gas detectors for WAXS and the area detector for SAXS (gas type or Mar165 CCD); the protocol also incorporates sample changing and temperature control for programmable data collection. The performance of the instrument is illustratedviaseveral different measurements, including (1) simultaneous SAXS/WAXS and differential scanning calorimetry for polymer crystallization, (2) structural evolution with a large ordering spacing of ∼250 nm in a supramolecular complex, (3) SAXS for polymer blends underin situdrawing, (4) SAXS and anomalous SAXS for unilamellar lipid vesicles and metalloprotein solutions, (5) anomalous GISAXS for oriented membranes of Br-labeled lipids embedded with peptides, and (6) GISAXS for silicate films formedin situat the air–water interface.

About this research paper

What this paper is about

At the National Synchrotron Radiation Research Center, a small/wide-angle X-ray scattering (SAXS/WAXS) instrument has been installed at the BL23A beamline with a superconducting wiggler insertion device. This beamline is equipped with double Si(111) crystal and double Mo/B4C multilayer monochromators, and an Si-based plane mirror that can selectively deflect the beam downwards for grazing-incidence SAXS (GISAXS) studies of air–liquid or liquid–liquid interfaces. The SAXS/WAXS instrument, situated in an experimental hutch, comprises collimation, sample and post-sample stages. Pinholes and slits have been incorporated into the beam collimation system spanning a distance of ∼5 m. The sample stage can accommodate various sample geometries for air–liquid interfaces, thin films, and solution and solid samples. The post-sample section consists of a 1 m WAXS section with two linear gas detectors, a vacuum bellows (1–4 m), a two-beamstop system and the SAXS detector system, all situated on a motorized optical bench for motion in six degrees of freedom. In particular, the vacuum bellows of a large inner diameter (260 mm) provides continuous changes of the sample-to-detector distance under vacuum. Synchronized SAXS and WAXS measurements are realizedviaa data-acquisition protocol that can integrate the two linear gas detectors for WAXS and the area detector for SAXS (gas type or Mar165 CCD); the protocol also incorporates sample changing and temperature control for programmable data collection. The performance of the instrument is illustratedviaseveral different measurements, including (1) simultaneous SAXS/WAXS and differential scanning calorimetry for polymer crystallization, (2) structural evolution with a large ordering spacing of ∼250 nm in a supramolecular complex, (3) SAXS for polymer blends underin situdrawing, (4) SAXS and anomalous SAXS for unilamellar lipid vesicles and metalloprotein solutions, (5) anomalous GISAXS for oriented membranes of Br-labeled lipids embedded with peptides, and (6) GISAXS for silicate films formedin situat the air–water interface.

Why it matters

OpenAlex reports 177 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

At the National Synchrotron Radiation Research Center, a small/wide-angle X-ray scattering (SAXS/WAXS) instrument has been installed at the BL23A beamline with a superconducting wiggler insertion device. This beamline is equipped with double Si(111) crystal and double Mo/B4C multilayer monochromators, and an Si-based plane mirror that can selectively deflect the beam downwards for grazing-incidence SAXS (GISAXS) studies of air–liquid or liquid–liquid interfaces. The SAXS/WAXS instrument, situated in an experimental hutch, comprises collimation, sample and post-sample stages. Pinholes and slits have been incorporated into the beam collimation system spanning a distance of ∼5 m. The sample stage can accommodate various sample geometries for air–liquid interfaces, thin films, and solution and solid samples. The post-sample section consists of a 1 m WAXS section with two linear gas detectors, a vacuum bellows (1–4 m), a two-beamstop system and the SAXS detector system, all situated on a motorized optical bench for motion in six degrees of freedom. In particular, the vacuum bellows of a large inner diameter (260 mm) provides continuous changes of the sample-to-detector distance under vacuum. Synchronized SAXS and WAXS measurements are realizedviaa data-acquisition protocol that can integrate the two linear gas detectors for WAXS and the area detector for SAXS (gas type or Mar165 CCD); the protocol also incorporates sample changing and temperature control for programmable data collection. The performance of the instrument is illustratedviaseveral different measurements, including (1) simultaneous SAXS/WAXS and differential scanning calorimetry for polymer crystallization, (2) structural evolution with a large ordering spacing of ∼250 nm in a supramolecular complex, (3) SAXS for polymer blends underin situdrawing, (4) SAXS and anomalous SAXS for unilamellar lipid vesicles and metalloprotein solutions, (5) anomalous GISAXS for oriented membranes of Br-labeled lipids embedded with peptides, and (6) GISAXS for silicate films formedin situat the air–water interface.

Key concepts: Beamline, Small-angle X-ray scattering, Collimated light, Optics, Materials science, Wiggler, Scattering, Detector

Related papers

Back to paper searchBrowse research topicsOriginal source
A small/wide-angle X-ray scattering instrument for structural characterization of air–liquid interfaces, thin films and bulk specimens — Research Paper | ScholarLens