1982Optica Acta International Journal of OpticsRequires access

Evaluation and Comparison Between the Collimator and the Detector Responses in a Scintillation Camera

Marı́a J. Yzuel, S. Millán, Sarah Miracle

Open publisher page 2 citations

Abstract

A method to study the relative influences of the collimator and the detector on the final image of a scintillation camera is proposed. The collimator response is studied by applying a technique based on the Fourier analysis for evaluating the point spread function (PSF) of parallel holes collimators. A mathematical expression for the PSF is obtained and from it the collimator MTF and plane sensitivity are evaluated. The scintillation camera response is obtained from the LSF measured experimentally. The detector response is obtained from these results. The method is applied to a Toshiba GCA 102 scintillation camera and from the results obtained the relative influences of the collimator and the detector on the image deterioration as a function of the object distance are discussed.

About this research paper

What this paper is about

A method to study the relative influences of the collimator and the detector on the final image of a scintillation camera is proposed. The collimator response is studied by applying a technique based on the Fourier analysis for evaluating the point spread function (PSF) of parallel holes collimators. A mathematical expression for the PSF is obtained and from it the collimator MTF and plane sensitivity are evaluated. The scintillation camera response is obtained from the LSF measured experimentally. The detector response is obtained from these results. The method is applied to a Toshiba GCA 102 scintillation camera and from the results obtained the relative influences of the collimator and the detector on the image deterioration as a function of the object distance are discussed.

Why it matters

OpenAlex reports 2 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A method to study the relative influences of the collimator and the detector on the final image of a scintillation camera is proposed. The collimator response is studied by applying a technique based on the Fourier analysis for evaluating the point spread function (PSF) of parallel holes collimators. A mathematical expression for the PSF is obtained and from it the collimator MTF and plane sensitivity are evaluated. The scintillation camera response is obtained from the LSF measured experimentally. The detector response is obtained from these results. The method is applied to a Toshiba GCA 102 scintillation camera and from the results obtained the relative influences of the collimator and the detector on the image deterioration as a function of the object distance are discussed.

Key concepts: Collimator, Scintillation, Optics, Detector, Physics, Optical transfer function, Sensitivity (control systems), Scintillator