1995Journal of High Resolution ChromatographyRequires access

Effect of ammonia on the response of the electron capture detector (ECD)

Mohamed Abdel‐Rehim, Mohamed Kamel, Moustapha Hassan

Open publisher page 2 citations

Abstract

Abstract The effect of ammonia on the electron capture detector (ECD) response has been investigated. Nitrogen with different ammonia concentrations (5–20%) was used as make‐up gas. Compared to pure nitrogen, the ECD response decreased when the ammonia concentration in the make‐up gas was 5%. However, the response increased when the ammonia concentration was 20%. The response factor of 4‐chlorophenol increased 4 fold when ammonia was 20%. Also, di‐ and tri‐chlorophenols increased by 30–50%. The nitroaromatic compounds responses increased by about 2–3.7 times with 20% ammonia in the make‐up gas. The signal‐to‐noise (S/N) increased when 20% ammonia in nitrogen was used as make‐up gas compared to pure nitrogen. Also, the detector linearity increased by 50% with ammonia.

About this research paper

What this paper is about

Abstract The effect of ammonia on the electron capture detector (ECD) response has been investigated. Nitrogen with different ammonia concentrations (5–20%) was used as make‐up gas. Compared to pure nitrogen, the ECD response decreased when the ammonia concentration in the make‐up gas was 5%. However, the response increased when the ammonia concentration was 20%. The response factor of 4‐chlorophenol increased 4 fold when ammonia was 20%. Also, di‐ and tri‐chlorophenols increased by 30–50%. The nitroaromatic compounds responses increased by about 2–3.7 times with 20% ammonia in the make‐up gas. The signal‐to‐noise (S/N) increased when 20% ammonia in nitrogen was used as make‐up gas compared to pure nitrogen. Also, the detector linearity increased by 50% with ammonia.

Why it matters

OpenAlex reports 2 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Abstract The effect of ammonia on the electron capture detector (ECD) response has been investigated. Nitrogen with different ammonia concentrations (5–20%) was used as make‐up gas. Compared to pure nitrogen, the ECD response decreased when the ammonia concentration in the make‐up gas was 5%. However, the response increased when the ammonia concentration was 20%. The response factor of 4‐chlorophenol increased 4 fold when ammonia was 20%. Also, di‐ and tri‐chlorophenols increased by 30–50%. The nitroaromatic compounds responses increased by about 2–3.7 times with 20% ammonia in the make‐up gas. The signal‐to‐noise (S/N) increased when 20% ammonia in nitrogen was used as make‐up gas compared to pure nitrogen. Also, the detector linearity increased by 50% with ammonia.

Key concepts: Ammonia, Ammonia gas, Chemistry, Nitrogen, Electron capture detector, Detector, Nitrogen gas, Inorganic chemistry

Related papers

Back to paper searchBrowse research topicsOriginal source
Effect of ammonia on the response of the electron capture detector (ECD) — Research Paper | ScholarLens