2006•Wiley Encyclopedia of Biomedical EngineeringRequires access

Sampling Theorem and Aliasing in Biomedical Signal Processing

Martin P. Mintchev

Open publisher page 2 citations

Abstract

Abstract Despite digital techniques for data acquisition and processing being widely used in biomedical research for quite some time, inappropriate signal conditioning and digitization are still potential pitfalls threatening both the reliability of the experiments and the proper interpretation of the acquired data. The aim of this chapter is to review: (1) the Sampling (Nyquist) Theorem; (2) the concept of aliasing; (3) the importance of antialiasing low‐pass filtering for eliminating the effect of aliasing and appropriately determining the sampling frequency; (4) the advantages of properly chosen filter cut‐off frequency and slope for determining the minimal required sampling frequency; and (5) the impact of incorrectly selected sampling frequency on the interpretation of biomedical data. In a case study, a model of electrogastrographic (EGG) recording is mixed with a model of electrocardiographic (EKG) artifact in an overall white noise environment. The resulting composite signal is low‐pass filtered and then digitized with a sampling frequency of 1 Hz. The cut‐off frequency of the first‐order low‐pass filter is altered from 0.5 Hz to 0.1 Hz. Amplitude frequency spectra of the digitized recordings are investigated to illustrate the effect of aliasing. An example with a real human electrogastrogram, in which an EKG artifact is present, illustrates the simulation results. When a first‐order antialiasing filter is used, at least a five‐fold difference between the filter cut‐off frequency and the sampling frequency is recommended for compliance with the Sampling Theorem. Increasing the order of the antialiasing filter can reduce the required sampling frequency, but can also make the entire instrumentation system underdamped, thus injecting oscillatory artifacts every time abrupt or sudden changes in the external conditions during the recording occur.

About this research paper

What this paper is about

Abstract Despite digital techniques for data acquisition and processing being widely used in biomedical research for quite some time, inappropriate signal conditioning and digitization are still potential pitfalls threatening both the reliability of the experiments and the proper interpretation of the acquired data. The aim of this chapter is to review: (1) the Sampling (Nyquist) Theorem; (2) the concept of aliasing; (3) the importance of antialiasing low‐pass filtering for eliminating the effect of aliasing and appropriately determining the sampling frequency; (4) the advantages of properly chosen filter cut‐off frequency and slope for determining the minimal required sampling frequency; and (5) the impact of incorrectly selected sampling frequency on the interpretation of biomedical data. In a case study, a model of electrogastrographic (EGG) recording is mixed with a model of electrocardiographic (EKG) artifact in an overall white noise environment. The resulting composite signal is low‐pass filtered and then digitized with a sampling frequency of 1 Hz. The cut‐off frequency of the first‐order low‐pass filter is altered from 0.5 Hz to 0.1 Hz. Amplitude frequency spectra of the digitized recordings are investigated to illustrate the effect of aliasing. An example with a real human electrogastrogram, in which an EKG artifact is present, illustrates the simulation results. When a first‐order antialiasing filter is used, at least a five‐fold difference between the filter cut‐off frequency and the sampling frequency is recommended for compliance with the Sampling Theorem. Increasing the order of the antialiasing filter can reduce the required sampling frequency, but can also make the entire instrumentation system underdamped, thus injecting oscillatory artifacts every time abrupt or sudden changes in the external conditions during the recording occur.

Why it matters

OpenAlex reports 2 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Abstract Despite digital techniques for data acquisition and processing being widely used in biomedical research for quite some time, inappropriate signal conditioning and digitization are still potential pitfalls threatening both the reliability of the experiments and the proper interpretation of the acquired data. The aim of this chapter is to review: (1) the Sampling (Nyquist) Theorem; (2) the concept of aliasing; (3) the importance of antialiasing low‐pass filtering for eliminating the effect of aliasing and appropriately determining the sampling frequency; (4) the advantages of properly chosen filter cut‐off frequency and slope for determining the minimal required sampling frequency; and (5) the impact of incorrectly selected sampling frequency on the interpretation of biomedical data. In a case study, a model of electrogastrographic (EGG) recording is mixed with a model of electrocardiographic (EKG) artifact in an overall white noise environment. The resulting composite signal is low‐pass filtered and then digitized with a sampling frequency of 1 Hz. The cut‐off frequency of the first‐order low‐pass filter is altered from 0.5 Hz to 0.1 Hz. Amplitude frequency spectra of the digitized recordings are investigated to illustrate the effect of aliasing. An example with a real human electrogastrogram, in which an EKG artifact is present, illustrates the simulation results. When a first‐order antialiasing filter is used, at least a five‐fold difference between the filter cut‐off frequency and the sampling frequency is recommended for compliance with the Sampling Theorem. Increasing the order of the antialiasing filter can reduce the required sampling frequency, but can also make the entire instrumentation system underdamped, thus injecting oscillatory artifacts every time abrupt or sudden changes in the external conditions during the recording occur.

Key concepts: Anti-aliasing filter, Aliasing, Sampling (signal processing), Nyquist–Shannon sampling theorem, Anti-aliasing, Nyquist frequency, Decimation, Filter (signal processing)

Related papers

Back to paper searchBrowse research topicsOriginal source
Sampling Theorem and Aliasing in Biomedical Signal Processing — Research Paper | ScholarLens