2011LuminescenceRequires access

Flow‐injection chemiluminescence method for the determination of chloramphenicol based on luminol–sodium periodate order‐transform second‐chemiluminescence reaction

Yafeng Zhuang, Sheng‐Nan Zhu, Wei Wei, Jie‐Li Li

Open publisher page 9 citations

Abstract

A new chemiluminescence (CL) reaction was observed when chloramphenicol solution was injected into the mixture after the end of the reaction of alkaline luminol and sodium periodate or sodium periodate was injected into the reaction mixture of chloramphenicol and alkaline luminol. This reaction is described as an order-transform second-chemiluminescence (OTSCL) reaction. The OTSCL method combined with a flow-injection technique was applied to the determination of chloramphenicol. The optimum conditions for the order-transform second-chemiluminescence emission were investigated. A mechanism for OTSCL has been proposed on the basis of the chemiluminescence kinetic characteristics, the UV-visible spectra and the chemiluminescent spectra. Under optimal experimental conditions, the CL response is proportional to the concentration of chloramphenicol over the range 5.0 × 10(-7)-5.0 × 10(-5) mol/L with a correlation coefficient of 0.9969 and a detection limit of 6.0 × 10(-8) mol/L (3σ). The relative standard deviation (RSD) for 11 repeated determinations of 5.0 × 10(-6) mol/L chloramphenicol is 1.7%. The method has been applied to the determination of chloramphenicol in pharmaceutical samples with satisfactory results.

About this research paper

What this paper is about

A new chemiluminescence (CL) reaction was observed when chloramphenicol solution was injected into the mixture after the end of the reaction of alkaline luminol and sodium periodate or sodium periodate was injected into the reaction mixture of chloramphenicol and alkaline luminol. This reaction is described as an order-transform second-chemiluminescence (OTSCL) reaction. The OTSCL method combined with a flow-injection technique was applied to the determination of chloramphenicol. The optimum conditions for the order-transform second-chemiluminescence emission were investigated. A mechanism for OTSCL has been proposed on the basis of the chemiluminescence kinetic characteristics, the UV-visible spectra and the chemiluminescent spectra. Under optimal experimental conditions, the CL response is proportional to the concentration of chloramphenicol over the range 5.0 × 10(-7)-5.0 × 10(-5) mol/L with a correlation coefficient of 0.9969 and a detection limit of 6.0 × 10(-8) mol/L (3σ). The relative standard deviation (RSD) for 11 repeated determinations of 5.0 × 10(-6) mol/L chloramphenicol is 1.7%. The method has been applied to the determination of chloramphenicol in pharmaceutical samples with satisfactory results.

Why it matters

OpenAlex reports 9 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A new chemiluminescence (CL) reaction was observed when chloramphenicol solution was injected into the mixture after the end of the reaction of alkaline luminol and sodium periodate or sodium periodate was injected into the reaction mixture of chloramphenicol and alkaline luminol. This reaction is described as an order-transform second-chemiluminescence (OTSCL) reaction. The OTSCL method combined with a flow-injection technique was applied to the determination of chloramphenicol. The optimum conditions for the order-transform second-chemiluminescence emission were investigated. A mechanism for OTSCL has been proposed on the basis of the chemiluminescence kinetic characteristics, the UV-visible spectra and the chemiluminescent spectra. Under optimal experimental conditions, the CL response is proportional to the concentration of chloramphenicol over the range 5.0 × 10(-7)-5.0 × 10(-5) mol/L with a correlation coefficient of 0.9969 and a detection limit of 6.0 × 10(-8) mol/L (3σ). The relative standard deviation (RSD) for 11 repeated determinations of 5.0 × 10(-6) mol/L chloramphenicol is 1.7%. The method has been applied to the determination of chloramphenicol in pharmaceutical samples with satisfactory results.

Key concepts: Chemiluminescence, Luminol, Sodium periodate, Chemistry, Periodate, Chromatography, Potassium periodate, Flow injection analysis

Related papers

Back to paper searchBrowse research topicsOriginal source
Flow‐injection chemiluminescence method for the determination of chloramphenicol based on luminol–sodium periodate order‐transform second‐chemiluminescence reaction — Research Paper | ScholarLens