Separation And Determination Of Benzoylated Polyamines (Spermidine Andspermine) Using Hplc Techniqe
Mohammed A.K. Alsouz
Abstract
Open-access reader
Mohammed A.K. Alsouz
Abstract
Open-access reader
A simple and sensitive reversed-phase high performance liquid chromatography (Rp -HPLC) was developed for separation and determination of polyamines (Spermidine and Spermine).Derivatization of polyamines was improved by dissolving benzoyl chloride in methanol to increase the detection of UV-Visible detector at λ max.254 nm.The benzoylated polyamines eluted by Rp-HPLC using methanol : water (52 : 48) as mobile phase.The detection limited of this method is (50ng/ml) .The separation was performed on BDS-DB (250 x 4.6 mm I.D) column at flow rate 1 ml/ min.using standard solutions.The retention time of two compounds (Spermidine and Spermine) were (7.7 , 8.5 min.)respectively, this method suggested that monitoring the Spermidine and Spermine compounds could play an important role in diagnosis of different types of carcinoma and fallow up chemo and radiotherapy treatments.
OpenAlex reports 2 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
A simple and sensitive reversed-phase high performance liquid chromatography (Rp -HPLC) was developed for separation and determination of polyamines (Spermidine and Spermine).Derivatization of polyamines was improved by dissolving benzoyl chloride in methanol to increase the detection of UV-Visible detector at λ max.254 nm.The benzoylated polyamines eluted by Rp-HPLC using methanol : water (52 : 48) as mobile phase.The detection limited of this method is (50ng/ml) .The separation was performed on BDS-DB (250 x 4.6 mm I.D) column at flow rate 1 ml/ min.using standard solutions.The retention time of two compounds (Spermidine and Spermine) were (7.7 , 8.5 min.)respectively, this method suggested that monitoring the Spermidine and Spermine compounds could play an important role in diagnosis of different types of carcinoma and fallow up chemo and radiotherapy treatments.
Key concepts: Spermidine, High-performance liquid chromatography, Spermine, Chromatography, Chemistry, Methanol, Derivatization, Benzoyl chloride