A new flow cytometric method for differential cell counting in ascitic fluid
Gert‐Jan M. van de Geijn, Marc van Gent, Natasja van Pul‐Bom, Marlène Beunis, Antonie J.P. van Tilburg, Tjin L. Njo
Abstract
Open-access reader
Gert‐Jan M. van de Geijn, Marc van Gent, Natasja van Pul‐Bom, Marlène Beunis, Antonie J.P. van Tilburg, Tjin L. Njo
Abstract
Open-access reader
Background Cell counts in bodyfluids such as ascitic fluid can be difficult to perform and report rapidly. The current gold standard for cell counting in body fluids is a suitable automated cell counter or a manual counting chamber, combined with differential counting on a cytospin. This technique has several disadvantages, so we designed a new flow cytometric test for cell counting in ascites. We compared this with an automatic cell counter (LH750, Beckman Coulter) and manual counting of cytospins. Methods Ascitic samples (n = 53) from 38 patients were studied. Polymorphonuclear neutrophils (PMN), lymphocytes, eosinophils, and macrophages were defined by flow cytometry. We compared this with our reference method: the absolute cell concentration calculated from the leukocyte concentration of the LH750 combined with a differential cell count performed manually on a cytospin. Results The outcomes of validation experiments (linearity, reproducibility, and detection limit) of the flow cytometric assay prove it is well suited for cell counting in ascitic fluid. Conclusions Based on analytical performance, flow cytometry is suited for cell counting in ascitic fluid. An ascitic fluid cell count is frequently ordered to detect spontaneous bacterial peritonitis (SBP). If the PMN count is ≥250 cells/mm3, SBP is highly suspected. Using our reference method, we calculated the sensitivities and specificities to detect ≥250 PMN cells/mm3for the LH750 (100% and 65%, respectively) and flow cytometric assay (100%, 100%). As flow cytometry is easier and faster we recommend this method for rapid cell counting in ascitic fluid. © 2014 International Clinical Cytometry Society
OpenAlex reports 25 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
Background Cell counts in bodyfluids such as ascitic fluid can be difficult to perform and report rapidly. The current gold standard for cell counting in body fluids is a suitable automated cell counter or a manual counting chamber, combined with differential counting on a cytospin. This technique has several disadvantages, so we designed a new flow cytometric test for cell counting in ascites. We compared this with an automatic cell counter (LH750, Beckman Coulter) and manual counting of cytospins. Methods Ascitic samples (n = 53) from 38 patients were studied. Polymorphonuclear neutrophils (PMN), lymphocytes, eosinophils, and macrophages were defined by flow cytometry. We compared this with our reference method: the absolute cell concentration calculated from the leukocyte concentration of the LH750 combined with a differential cell count performed manually on a cytospin. Results The outcomes of validation experiments (linearity, reproducibility, and detection limit) of the flow cytometric assay prove it is well suited for cell counting in ascitic fluid. Conclusions Based on analytical performance, flow cytometry is suited for cell counting in ascitic fluid. An ascitic fluid cell count is frequently ordered to detect spontaneous bacterial peritonitis (SBP). If the PMN count is ≥250 cells/mm3, SBP is highly suspected. Using our reference method, we calculated the sensitivities and specificities to detect ≥250 PMN cells/mm3for the LH750 (100% and 65%, respectively) and flow cytometric assay (100%, 100%). As flow cytometry is easier and faster we recommend this method for rapid cell counting in ascitic fluid. © 2014 International Clinical Cytometry Society
Key concepts: Ascitic fluid, Flow cytometry, Differential (mechanical device), Cell counting, Pathology, Medicine, Computer science, Immunology