1991Clinical ChemistryRequires access

Effects of serum-isolated vs synthetic bilirubin-albumin complexes on dye-binding methods for estimating serum albumin

Hiroshi Ihara, H Nakamura, Yutaka Aoki, Toshiaki Aoki, Mitsutaka Yoshida

Open publisher page 18 citations

Abstract

Bush and Reed reported (Clin Chem 1987;33:821-3) that the reaction of albumin with bromcresol purple but not with bromcresol green underestimated the concentration of albumin in synthetically obtained bilirubin-albumin (Bd) by 29%. Their unproven assumption was that chemically synthesized Bd behaved in a manner indistinguishable from the natural Bd in icteric serum. Here we verify that Bd, whether synthetically obtained or isolated from serum, causes an underestimation of albumin in the bromcresol purple but not in the bromcresol green method. The molar ratio of Bd from either source to underestimated albumin approximates 1.0, suggesting that one molecule of Bd would react equivalently to a molecule of albumin in the bromcresol purple method. This underestimation might falsely suggest hypoalbuminemia in patients with increased serum Bd.

About this research paper

What this paper is about

Bush and Reed reported (Clin Chem 1987;33:821-3) that the reaction of albumin with bromcresol purple but not with bromcresol green underestimated the concentration of albumin in synthetically obtained bilirubin-albumin (Bd) by 29%. Their unproven assumption was that chemically synthesized Bd behaved in a manner indistinguishable from the natural Bd in icteric serum. Here we verify that Bd, whether synthetically obtained or isolated from serum, causes an underestimation of albumin in the bromcresol purple but not in the bromcresol green method. The molar ratio of Bd from either source to underestimated albumin approximates 1.0, suggesting that one molecule of Bd would react equivalently to a molecule of albumin in the bromcresol purple method. This underestimation might falsely suggest hypoalbuminemia in patients with increased serum Bd.

Why it matters

OpenAlex reports 18 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Bush and Reed reported (Clin Chem 1987;33:821-3) that the reaction of albumin with bromcresol purple but not with bromcresol green underestimated the concentration of albumin in synthetically obtained bilirubin-albumin (Bd) by 29%. Their unproven assumption was that chemically synthesized Bd behaved in a manner indistinguishable from the natural Bd in icteric serum. Here we verify that Bd, whether synthetically obtained or isolated from serum, causes an underestimation of albumin in the bromcresol purple but not in the bromcresol green method. The molar ratio of Bd from either source to underestimated albumin approximates 1.0, suggesting that one molecule of Bd would react equivalently to a molecule of albumin in the bromcresol purple method. This underestimation might falsely suggest hypoalbuminemia in patients with increased serum Bd.

Key concepts: Albumin, Bilirubin, Serum albumin, Chemistry, Serum bilirubin, Internal medicine, Chromatography, Medicine

Related papers

Back to paper searchBrowse research topicsOriginal source
Effects of serum-isolated vs synthetic bilirubin-albumin complexes on dye-binding methods for estimating serum albumin — Research Paper | ScholarLens