1999•arXiv (Cornell University)Open access

An All-Solid State Central Tracker for the Proposed DESY Electron-Positron Linear Collider

Bruce J. King

Open full text 1 citations

Abstract

This report describes an all-solid state central tracker which is intended for use in a detector at the proposed DESY 500 GeV electron-positron linear collider or a similar accelerator. The precise position measurements from position-sensitive silicon detectors give the tracker an outstanding momentum resolution for high momentum tracks: sigma_p/p^2 = 3.6 x 10^{-5} (GeV/c)^{-1} for tracks perpendicular to the beam-line. The report concludes with an example layout for a detector which uses this central tracker.

Open-access reader

About this research paper

What this paper is about

This report describes an all-solid state central tracker which is intended for use in a detector at the proposed DESY 500 GeV electron-positron linear collider or a similar accelerator. The precise position measurements from position-sensitive silicon detectors give the tracker an outstanding momentum resolution for high momentum tracks: sigma_p/p^2 = 3.6 x 10^{-5} (GeV/c)^{-1} for tracks perpendicular to the beam-line. The report concludes with an example layout for a detector which uses this central tracker.

Why it matters

OpenAlex reports 1 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

This report describes an all-solid state central tracker which is intended for use in a detector at the proposed DESY 500 GeV electron-positron linear collider or a similar accelerator. The precise position measurements from position-sensitive silicon detectors give the tracker an outstanding momentum resolution for high momentum tracks: sigma_p/p^2 = 3.6 x 10^{-5} (GeV/c)^{-1} for tracks perpendicular to the beam-line. The report concludes with an example layout for a detector which uses this central tracker.

Key concepts: DESY, Physics, Collider, Nuclear physics, Detector, Tracking (education), Positron, Momentum (technical analysis)

Related papers

Back to paper searchBrowse research topicsOriginal source
An All-Solid State Central Tracker for the Proposed DESY Electron-Positron Linear Collider — Research Paper | ScholarLens