Bunch Shape Monitors for the DESY H/sup -/ linac
A.V. Feschenko, A.V. Liiou, A.N. Mirzojan, Alexander Menshov, P. N. Ostroumov, N. Holtkamp, C. Kleffner, M. Nagl, I. Peperkorn
Abstract
A.V. Feschenko, A.V. Liiou, A.N. Mirzojan, Alexander Menshov, P. N. Ostroumov, N. Holtkamp, C. Kleffner, M. Nagl, I. Peperkorn
Abstract
For better tuning and control of the longitudinal beam parameters two Bunch Shape Monitors (BSM) and one Bunch Length and Velocity Detector (BLVD) have been developed and installed in the DESY H/sup -/ linac (Linac-III). The BSMs have a standard function to measure the longitudinal distribution of particles in bunches and the mechanical layout has been optimized in order to fit the extremely narrow space between the DTL tanks. The BLVD has an additional feature to measure the beam absolute energy and is installed downstream of the linac. Due to the use of a thin wire as a source of secondary electrons the devices can be used as a nondestructive beam diagnostic tool during linac operation. The performance of the BSMs as well as the results of the Linac-III beam studies using the new devices are presented.
OpenAlex reports 4 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
For better tuning and control of the longitudinal beam parameters two Bunch Shape Monitors (BSM) and one Bunch Length and Velocity Detector (BLVD) have been developed and installed in the DESY H/sup -/ linac (Linac-III). The BSMs have a standard function to measure the longitudinal distribution of particles in bunches and the mechanical layout has been optimized in order to fit the extremely narrow space between the DTL tanks. The BLVD has an additional feature to measure the beam absolute energy and is installed downstream of the linac. Due to the use of a thin wire as a source of secondary electrons the devices can be used as a nondestructive beam diagnostic tool during linac operation. The performance of the BSMs as well as the results of the Linac-III beam studies using the new devices are presented.
Key concepts: DESY, Linear particle accelerator, Bunches, Beam (structure), Physics, Particle accelerator, Optics, Detector