Comparison of lesion enhancement on spin-echo and gradient-echo images.

Phylliss M. Chappell, Norbert J. Pelc, Thomas Foo, Gary H. Glover, S. P. Haros, Dieter R. Enzmann

Open full text 63 citations

Abstract

PURPOSE: To compare lesion enhancement after injection of gadopentetate dimeglumine on spin-echo and gradient-echo T1-weighted images. METHODS: A total of 48 contrast-enhancing intracranial lesions were evaluated using a spin-echo and two gradient-echo T1-weighted pulse sequences. Percent contrast, contrast-to-noise, and signal-to-noise measurements were made on the spin-echo T1-weighted, three-dimensional gradient-echo, and multiplanar gradient-echo sequences. RESULTS: The measurements were somewhat different for the following categories of lesions: extraaxial, intraaxial with edema, and intraaxial without edema. The latter group provided the greatest diagnostic challenge: three of 19 such lesions 1 cm in size or smaller could not be identified on three-dimensional gradient-echo images, and one could not be identified on multi-planar gradient-echo images. The spin-echo T1-weighted sequence demonstrated significantly higher percent contrast (P < .05) and greater contrast to noise (P < .03) than either gradient-echo sequence for these small intraaxial lesions without edema. For extraaxial and intraaxial lesions with edema, percent C was similar for spin-echo T1-weighted and three-dimensional gradient-echo images, while contrast to noise was greater for spin-echo T1-weighted images. This reflected greater tissue noise with gradient-echo sequences. CONCLUSION: The T1-weighted spin-echo sequence was preferred for detecting the full spectrum of contrast-enhancing lesions of the central nervous system.

About this research paper

What this paper is about

PURPOSE: To compare lesion enhancement after injection of gadopentetate dimeglumine on spin-echo and gradient-echo T1-weighted images. METHODS: A total of 48 contrast-enhancing intracranial lesions were evaluated using a spin-echo and two gradient-echo T1-weighted pulse sequences. Percent contrast, contrast-to-noise, and signal-to-noise measurements were made on the spin-echo T1-weighted, three-dimensional gradient-echo, and multiplanar gradient-echo sequences. RESULTS: The measurements were somewhat different for the following categories of lesions: extraaxial, intraaxial with edema, and intraaxial without edema. The latter group provided the greatest diagnostic challenge: three of 19 such lesions 1 cm in size or smaller could not be identified on three-dimensional gradient-echo images, and one could not be identified on multi-planar gradient-echo images. The spin-echo T1-weighted sequence demonstrated significantly higher percent contrast (P < .05) and greater contrast to noise (P < .03) than either gradient-echo sequence for these small intraaxial lesions without edema. For extraaxial and intraaxial lesions with edema, percent C was similar for spin-echo T1-weighted and three-dimensional gradient-echo images, while contrast to noise was greater for spin-echo T1-weighted images. This reflected greater tissue noise with gradient-echo sequences. CONCLUSION: The T1-weighted spin-echo sequence was preferred for detecting the full spectrum of contrast-enhancing lesions of the central nervous system.

Why it matters

OpenAlex reports 63 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

PURPOSE: To compare lesion enhancement after injection of gadopentetate dimeglumine on spin-echo and gradient-echo T1-weighted images. METHODS: A total of 48 contrast-enhancing intracranial lesions were evaluated using a spin-echo and two gradient-echo T1-weighted pulse sequences. Percent contrast, contrast-to-noise, and signal-to-noise measurements were made on the spin-echo T1-weighted, three-dimensional gradient-echo, and multiplanar gradient-echo sequences. RESULTS: The measurements were somewhat different for the following categories of lesions: extraaxial, intraaxial with edema, and intraaxial without edema. The latter group provided the greatest diagnostic challenge: three of 19 such lesions 1 cm in size or smaller could not be identified on three-dimensional gradient-echo images, and one could not be identified on multi-planar gradient-echo images. The spin-echo T1-weighted sequence demonstrated significantly higher percent contrast (P < .05) and greater contrast to noise (P < .03) than either gradient-echo sequence for these small intraaxial lesions without edema. For extraaxial and intraaxial lesions with edema, percent C was similar for spin-echo T1-weighted and three-dimensional gradient-echo images, while contrast to noise was greater for spin-echo T1-weighted images. This reflected greater tissue noise with gradient-echo sequences. CONCLUSION: The T1-weighted spin-echo sequence was preferred for detecting the full spectrum of contrast-enhancing lesions of the central nervous system.

Key concepts: Spin echo, Echo (communications protocol), Gradient echo, Medicine, Nuclear magnetic resonance, Contrast (vision), Echo time, Lesion

Related papers

Back to paper searchBrowse research topicsOriginal source
Comparison of lesion enhancement on spin-echo and gradient-echo images. — Research Paper | ScholarLens