2008Magnetic Resonance in Medical SciencesOpen access

Contrast-enhanced MR Imaging of Metastatic Brain Tumor at 3 Tesla: Utility of T1-weighted SPACE Compared with 2D Spin Echo and 3D Gradient Echo Sequence

Tomohiro Komada, Shinji Naganawa, Hiroshi Ogawa, Masaya Matsushima, Seiji Kubota, Hisashi Kawai, Hiroshi Fukatsu, Mitsuru Ikeda, Minako Kawamura, Yasuo Sakurai, Katsuya Maruyama

Open full text 93 citations

Abstract

We evaluated the newly developed whole-brain, isotropic, 3-dimensional turbo spin-echo imaging with variable flip angle echo train (SPACE) for contrast-enhanced T(1)-weighted imaging in detecting brain metastases at 3 tesla (T). Twenty-two patients with suspected brain metastases underwent postcontrast study with SPACE, magnetization-prepared rapid gradient-echo (MP-RAGE), and 2-dimensional T(1)-weighted spin echo (2D-SE) imaging at 3T. We quantitatively compared SPACE, MP-RAGE, and 2D-SE images by using signal-to-noise ratios (SNRs) for gray matter (GM) and white matter (WM) and contrast-to-noise ratios (CNRs) for GM-to-WM, lesion-to-GM, and lesion-to-WM. Two blinded radiologists evaluated the detection of brain metastases by segment-by-segment analysis and continuously-distributed test. The CNR between GM and WM was significantly higher on MP-RAGE images than on SPACE images (P<0.01). The CNRs for lesion-to-GM and lesion-to-WM were significantly higher on SPACE images than on MP-RAGE images (P<0.01). There was no significant difference in each sequence in detection of brain metastases by segment-by-segment analysis and the continuously-distributed test. However, in some cases, the lesions were easier to detect in SPACE images than in other sequences, and also the vascular signals, which sometimes mimic lesions in MP-RAGE and 2D-SE images, were suppressed in SPACE images. In detection of brain metastases at 3T magnetic resonance (MR) imaging, SPACE imaging may provide an effective, alternative approach to MP-RAGE imaging for 3D T(1)-weighted imaging.

Open-access reader

About this research paper

What this paper is about

We evaluated the newly developed whole-brain, isotropic, 3-dimensional turbo spin-echo imaging with variable flip angle echo train (SPACE) for contrast-enhanced T(1)-weighted imaging in detecting brain metastases at 3 tesla (T). Twenty-two patients with suspected brain metastases underwent postcontrast study with SPACE, magnetization-prepared rapid gradient-echo (MP-RAGE), and 2-dimensional T(1)-weighted spin echo (2D-SE) imaging at 3T. We quantitatively compared SPACE, MP-RAGE, and 2D-SE images by using signal-to-noise ratios (SNRs) for gray matter (GM) and white matter (WM) and contrast-to-noise ratios (CNRs) for GM-to-WM, lesion-to-GM, and lesion-to-WM. Two blinded radiologists evaluated the detection of brain metastases by segment-by-segment analysis and continuously-distributed test. The CNR between GM and WM was significantly higher on MP-RAGE images than on SPACE images (P<0.01). The CNRs for lesion-to-GM and lesion-to-WM were significantly higher on SPACE images than on MP-RAGE images (P<0.01). There was no significant difference in each sequence in detection of brain metastases by segment-by-segment analysis and the continuously-distributed test. However, in some cases, the lesions were easier to detect in SPACE images than in other sequences, and also the vascular signals, which sometimes mimic lesions in MP-RAGE and 2D-SE images, were suppressed in SPACE images. In detection of brain metastases at 3T magnetic resonance (MR) imaging, SPACE imaging may provide an effective, alternative approach to MP-RAGE imaging for 3D T(1)-weighted imaging.

Why it matters

OpenAlex reports 93 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

We evaluated the newly developed whole-brain, isotropic, 3-dimensional turbo spin-echo imaging with variable flip angle echo train (SPACE) for contrast-enhanced T(1)-weighted imaging in detecting brain metastases at 3 tesla (T). Twenty-two patients with suspected brain metastases underwent postcontrast study with SPACE, magnetization-prepared rapid gradient-echo (MP-RAGE), and 2-dimensional T(1)-weighted spin echo (2D-SE) imaging at 3T. We quantitatively compared SPACE, MP-RAGE, and 2D-SE images by using signal-to-noise ratios (SNRs) for gray matter (GM) and white matter (WM) and contrast-to-noise ratios (CNRs) for GM-to-WM, lesion-to-GM, and lesion-to-WM. Two blinded radiologists evaluated the detection of brain metastases by segment-by-segment analysis and continuously-distributed test. The CNR between GM and WM was significantly higher on MP-RAGE images than on SPACE images (P<0.01). The CNRs for lesion-to-GM and lesion-to-WM were significantly higher on SPACE images than on MP-RAGE images (P<0.01). There was no significant difference in each sequence in detection of brain metastases by segment-by-segment analysis and the continuously-distributed test. However, in some cases, the lesions were easier to detect in SPACE images than in other sequences, and also the vascular signals, which sometimes mimic lesions in MP-RAGE and 2D-SE images, were suppressed in SPACE images. In detection of brain metastases at 3T magnetic resonance (MR) imaging, SPACE imaging may provide an effective, alternative approach to MP-RAGE imaging for 3D T(1)-weighted imaging.

Key concepts: Medicine, Magnetic resonance imaging, Nuclear medicine, Lesion, Spin echo, Nuclear magnetic resonance, Fast spin echo, Magnetization transfer

Related papers

Back to paper searchBrowse research topicsOriginal source
Contrast-enhanced MR Imaging of Metastatic Brain Tumor at 3 Tesla: Utility of T1-weighted SPACE Compared with 2D Spin Echo and 3D Gradient Echo Sequence — Research Paper | ScholarLens