Abstract

BACKGROUND: Since the introduction of the first radioimmunoassay, several improvements have been made in the design of immunoassays such as method of antibody production, labeling, automation and detection technology. We performed an analytical evaluation of the new electrochemiluminescent immunoassay (ECLIA) for serum TSH, FT4 and T3 in the Elecsys 2010 immunoassay system and compared the results of this method with those of radioimmunoassay ( RIA) [immunoradiometric (IRMA) for TSH] and Elisa. METHODS: Fasting serum from 112 hypo, hyper and euthyroid patients were used to evaluate the minimum detectable concentration, intra- and inter-assay precisions for TSH, FT4, T3, linearity for TSH assay and method comparison study. RESULTS: Within the analytical range tested, intra-assay coefficient of variation was < 2.3% for TSH, 2.3% for FT4 and 7.8% for T3. The inter-assay coefficient of variation was < 2.9% for TSH, 2.5% for FT4 and 12.3% for T3. The measurement of diluted sera indicated a desirable percentage of recovery for TSH. No correlation was found between Elecsys 2010 and Elisa /IRMA for TSH. The comparison of results of the Elecsys ECLIA assay with those of Elisa and RIA for T4 were: T4 (ECLIA) = -0.612+0.999, T4 (Elisa, r= 0.88) and T4 (ECLIA)=0.642+0.942 T4 (RIA, r=0.957), while ECLIA assay with Elisa and RIA for T3 were: T3 (ECLIA)= 0.242+0.908 T3 (Elisa, r=0.8) and T3 (ECLIA) = -0.029+1.01 T3 (RIA, r=0.957). CONCLUSION: The results show that Elecsys 2010 is an automated reliable, efficient and technically excellent instrument to use in the measurement of serum TSH, T4 and T3.

About this research paper

What this paper is about

BACKGROUND: Since the introduction of the first radioimmunoassay, several improvements have been made in the design of immunoassays such as method of antibody production, labeling, automation and detection technology. We performed an analytical evaluation of the new electrochemiluminescent immunoassay (ECLIA) for serum TSH, FT4 and T3 in the Elecsys 2010 immunoassay system and compared the results of this method with those of radioimmunoassay ( RIA) [immunoradiometric (IRMA) for TSH] and Elisa. METHODS: Fasting serum from 112 hypo, hyper and euthyroid patients were used to evaluate the minimum detectable concentration, intra- and inter-assay precisions for TSH, FT4, T3, linearity for TSH assay and method comparison study. RESULTS: Within the analytical range tested, intra-assay coefficient of variation was < 2.3% for TSH, 2.3% for FT4 and 7.8% for T3. The inter-assay coefficient of variation was < 2.9% for TSH, 2.5% for FT4 and 12.3% for T3. The measurement of diluted sera indicated a desirable percentage of recovery for TSH. No correlation was found between Elecsys 2010 and Elisa /IRMA for TSH. The comparison of results of the Elecsys ECLIA assay with those of Elisa and RIA for T4 were: T4 (ECLIA) = -0.612+0.999, T4 (Elisa, r= 0.88) and T4 (ECLIA)=0.642+0.942 T4 (RIA, r=0.957), while ECLIA assay with Elisa and RIA for T3 were: T3 (ECLIA)= 0.242+0.908 T3 (Elisa, r=0.8) and T3 (ECLIA) = -0.029+1.01 T3 (RIA, r=0.957). CONCLUSION: The results show that Elecsys 2010 is an automated reliable, efficient and technically excellent instrument to use in the measurement of serum TSH, T4 and T3.

Why it matters

OpenAlex reports 24 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

BACKGROUND: Since the introduction of the first radioimmunoassay, several improvements have been made in the design of immunoassays such as method of antibody production, labeling, automation and detection technology. We performed an analytical evaluation of the new electrochemiluminescent immunoassay (ECLIA) for serum TSH, FT4 and T3 in the Elecsys 2010 immunoassay system and compared the results of this method with those of radioimmunoassay ( RIA) [immunoradiometric (IRMA) for TSH] and Elisa. METHODS: Fasting serum from 112 hypo, hyper and euthyroid patients were used to evaluate the minimum detectable concentration, intra- and inter-assay precisions for TSH, FT4, T3, linearity for TSH assay and method comparison study. RESULTS: Within the analytical range tested, intra-assay coefficient of variation was < 2.3% for TSH, 2.3% for FT4 and 7.8% for T3. The inter-assay coefficient of variation was < 2.9% for TSH, 2.5% for FT4 and 12.3% for T3. The measurement of diluted sera indicated a desirable percentage of recovery for TSH. No correlation was found between Elecsys 2010 and Elisa /IRMA for TSH. The comparison of results of the Elecsys ECLIA assay with those of Elisa and RIA for T4 were: T4 (ECLIA) = -0.612+0.999, T4 (Elisa, r= 0.88) and T4 (ECLIA)=0.642+0.942 T4 (RIA, r=0.957), while ECLIA assay with Elisa and RIA for T3 were: T3 (ECLIA)= 0.242+0.908 T3 (Elisa, r=0.8) and T3 (ECLIA) = -0.029+1.01 T3 (RIA, r=0.957). CONCLUSION: The results show that Elecsys 2010 is an automated reliable, efficient and technically excellent instrument to use in the measurement of serum TSH, T4 and T3.