1994PubMedOpen access

Optimization of gradient-echo MR for calcium detection.

Mark Henkelman, Walter Kucharczyk

Open full text 18 citations

Abstract

PURPOSE: To determine optimal MR gradient-echo sequences for the visualization of calcium in neurologic MR. METHOD: The dependence of signal intensity and image contrast on the imaging parameters repetition time, echo time, flip angle, and spoiling were measured for hydroxyapatite samples. Calculations of signal intensity were shown to correspond to these measures. RESULTS: Optimum detectability was obtained with an echo time of 29 msec and was independent of spoiling. As repetition time ranged from 30 msec to 700 msec, the optimal flip angle ranged from 17 degrees to 66 degrees. CONCLUSIONS: Gradient-echo sequences that optimize the contrast for detection of calcium in neurologic imaging have been determined.

About this research paper

What this paper is about

PURPOSE: To determine optimal MR gradient-echo sequences for the visualization of calcium in neurologic MR. METHOD: The dependence of signal intensity and image contrast on the imaging parameters repetition time, echo time, flip angle, and spoiling were measured for hydroxyapatite samples. Calculations of signal intensity were shown to correspond to these measures. RESULTS: Optimum detectability was obtained with an echo time of 29 msec and was independent of spoiling. As repetition time ranged from 30 msec to 700 msec, the optimal flip angle ranged from 17 degrees to 66 degrees. CONCLUSIONS: Gradient-echo sequences that optimize the contrast for detection of calcium in neurologic imaging have been determined.

Why it matters

OpenAlex reports 18 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

PURPOSE: To determine optimal MR gradient-echo sequences for the visualization of calcium in neurologic MR. METHOD: The dependence of signal intensity and image contrast on the imaging parameters repetition time, echo time, flip angle, and spoiling were measured for hydroxyapatite samples. Calculations of signal intensity were shown to correspond to these measures. RESULTS: Optimum detectability was obtained with an echo time of 29 msec and was independent of spoiling. As repetition time ranged from 30 msec to 700 msec, the optimal flip angle ranged from 17 degrees to 66 degrees. CONCLUSIONS: Gradient-echo sequences that optimize the contrast for detection of calcium in neurologic imaging have been determined.

Key concepts: Flip angle, Echo time, Gradient echo, Echo (communications protocol), Contrast (vision), SIGNAL (programming language), Nuclear magnetic resonance, Medicine

Related papers

Back to paper searchBrowse research topicsOriginal source
Optimization of gradient-echo MR for calcium detection. — Research Paper | ScholarLens