1998RadiologyRequires access

MR imaging of the hippocampus: measurement of T2 with four dual-echo techniques.

Elias R. Melhem, Richard E. Whitehead, R. J. Bert, Shelton D. Caruthers

Open publisher page 10 citations

Abstract

PURPOSE: To assess the effect of cerebrospinal fluid (CSF) signal nulling and different magnetic resonance (MR) imaging read-out implementations on the precision of T2 measurements in the hippocampus. MATERIALS AND METHODS: Oblique coronal MR imaging was performed in 12 healthy volunteers by using four dual-echo MR sequences: conventional spin-echo (SE), fast SE, gradient-echo and SE (GRASE), and fast fluid-attenuated inversion-recovery (FLAIR) imaging. T2 measurements were obtained from T2 maps derived from regions of interest within the head of both hippocampi. T2 measurements obtained with the four MR sequences were compared, as were differences in T2 between right and left hippocampi. Interrater and test-retest consistency were determined. RESULTS: Fast FLAIR imaging provided the smallest normal range and SD of T2 measurements. Fast FLAIR and fast SE imaging provided the smallest coefficients of variation. GRASE imaging provided a lower coefficient of variation than that of conventional SE. The mean difference between left and right hippocampi was smallest at fast FLAIR imaging. CONCLUSION: Use of a CSF-nulling inversion prepulse, fast SE read-out, or GRASE read-out MR sequence helps improve the precision of the hippocampal T2 measurements in comparison with use of conventional SE imaging. T2 measurements obtained at dual-echo fast FLAIR imaging may help detect subtle hippocampal abnormalities.

About this research paper

What this paper is about

PURPOSE: To assess the effect of cerebrospinal fluid (CSF) signal nulling and different magnetic resonance (MR) imaging read-out implementations on the precision of T2 measurements in the hippocampus. MATERIALS AND METHODS: Oblique coronal MR imaging was performed in 12 healthy volunteers by using four dual-echo MR sequences: conventional spin-echo (SE), fast SE, gradient-echo and SE (GRASE), and fast fluid-attenuated inversion-recovery (FLAIR) imaging. T2 measurements were obtained from T2 maps derived from regions of interest within the head of both hippocampi. T2 measurements obtained with the four MR sequences were compared, as were differences in T2 between right and left hippocampi. Interrater and test-retest consistency were determined. RESULTS: Fast FLAIR imaging provided the smallest normal range and SD of T2 measurements. Fast FLAIR and fast SE imaging provided the smallest coefficients of variation. GRASE imaging provided a lower coefficient of variation than that of conventional SE. The mean difference between left and right hippocampi was smallest at fast FLAIR imaging. CONCLUSION: Use of a CSF-nulling inversion prepulse, fast SE read-out, or GRASE read-out MR sequence helps improve the precision of the hippocampal T2 measurements in comparison with use of conventional SE imaging. T2 measurements obtained at dual-echo fast FLAIR imaging may help detect subtle hippocampal abnormalities.

Why it matters

OpenAlex reports 10 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

PURPOSE: To assess the effect of cerebrospinal fluid (CSF) signal nulling and different magnetic resonance (MR) imaging read-out implementations on the precision of T2 measurements in the hippocampus. MATERIALS AND METHODS: Oblique coronal MR imaging was performed in 12 healthy volunteers by using four dual-echo MR sequences: conventional spin-echo (SE), fast SE, gradient-echo and SE (GRASE), and fast fluid-attenuated inversion-recovery (FLAIR) imaging. T2 measurements were obtained from T2 maps derived from regions of interest within the head of both hippocampi. T2 measurements obtained with the four MR sequences were compared, as were differences in T2 between right and left hippocampi. Interrater and test-retest consistency were determined. RESULTS: Fast FLAIR imaging provided the smallest normal range and SD of T2 measurements. Fast FLAIR and fast SE imaging provided the smallest coefficients of variation. GRASE imaging provided a lower coefficient of variation than that of conventional SE. The mean difference between left and right hippocampi was smallest at fast FLAIR imaging. CONCLUSION: Use of a CSF-nulling inversion prepulse, fast SE read-out, or GRASE read-out MR sequence helps improve the precision of the hippocampal T2 measurements in comparison with use of conventional SE imaging. T2 measurements obtained at dual-echo fast FLAIR imaging may help detect subtle hippocampal abnormalities.

Key concepts: Medicine, Echo (communications protocol), Hippocampus, Dual (grammatical number), Nuclear medicine, Nuclear magnetic resonance, Internal medicine, Literature

Related papers

Back to paper searchBrowse research topicsOriginal source
MR imaging of the hippocampus: measurement of T2 with four dual-echo techniques. — Research Paper | ScholarLens