1992American Journal of Physiology-Endocrinology and MetabolismRequires access

Hepatic glucagon sensitivity and fasting glucose concentration in normal dogs

David C. Bradley, Richard N. Bergman

Open publisher page 4 citations

Abstract

We assessed hepatic glucagon sensitivity in overnight-fasted, conscious dogs. Six pancreatic replacement protocols were performed in each of five animals. Somatostatin was infused to inhibit endogenous insulin and glucagon, insulin was replaced intraportally at 200 microU.min-1.kg-1, and glucagon was infused intraportally at 0, 0.6, 1, 2, 5, or 20 ng.min-1.kg-1. One intravenous glucose tolerance test was also performed in each animal for measurement of insulin sensitivity (SI). During hormone replacement at a given glucagon dose, plasma glucose differed substantially among animals (P = 0.003). Therefore the dose required for restoration of euglycemia ("glucagon requirement") varied nearly sevenfold among animals, suggesting appreciable differences in glucagon sensitivity (GS). The latter was quantitated in individual animals as the initial slope of integrated glucose output vs. glucagon concentration. GS varied from 0.22 to 3.9 mg.kg-1.pg-1.ml among various animals and was inversely and significantly related to glucagon requirement. SI varied less (approximately 4-fold) and was not associated with glucagon requirement. These observations suggested that interanimal differences in glucose during hormone replacement were the result of substantial differences in GS. In addition, we found the GS of a given animal to be highly associated (P = 0.01) with its fasting glucose level. We conclude that GS varies substantially, and as such may be an important determinant of the fasting glucose level in normal animals.

About this research paper

What this paper is about

We assessed hepatic glucagon sensitivity in overnight-fasted, conscious dogs. Six pancreatic replacement protocols were performed in each of five animals. Somatostatin was infused to inhibit endogenous insulin and glucagon, insulin was replaced intraportally at 200 microU.min-1.kg-1, and glucagon was infused intraportally at 0, 0.6, 1, 2, 5, or 20 ng.min-1.kg-1. One intravenous glucose tolerance test was also performed in each animal for measurement of insulin sensitivity (SI). During hormone replacement at a given glucagon dose, plasma glucose differed substantially among animals (P = 0.003). Therefore the dose required for restoration of euglycemia ("glucagon requirement") varied nearly sevenfold among animals, suggesting appreciable differences in glucagon sensitivity (GS). The latter was quantitated in individual animals as the initial slope of integrated glucose output vs. glucagon concentration. GS varied from 0.22 to 3.9 mg.kg-1.pg-1.ml among various animals and was inversely and significantly related to glucagon requirement. SI varied less (approximately 4-fold) and was not associated with glucagon requirement. These observations suggested that interanimal differences in glucose during hormone replacement were the result of substantial differences in GS. In addition, we found the GS of a given animal to be highly associated (P = 0.01) with its fasting glucose level. We conclude that GS varies substantially, and as such may be an important determinant of the fasting glucose level in normal animals.

Why it matters

OpenAlex reports 4 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

We assessed hepatic glucagon sensitivity in overnight-fasted, conscious dogs. Six pancreatic replacement protocols were performed in each of five animals. Somatostatin was infused to inhibit endogenous insulin and glucagon, insulin was replaced intraportally at 200 microU.min-1.kg-1, and glucagon was infused intraportally at 0, 0.6, 1, 2, 5, or 20 ng.min-1.kg-1. One intravenous glucose tolerance test was also performed in each animal for measurement of insulin sensitivity (SI). During hormone replacement at a given glucagon dose, plasma glucose differed substantially among animals (P = 0.003). Therefore the dose required for restoration of euglycemia ("glucagon requirement") varied nearly sevenfold among animals, suggesting appreciable differences in glucagon sensitivity (GS). The latter was quantitated in individual animals as the initial slope of integrated glucose output vs. glucagon concentration. GS varied from 0.22 to 3.9 mg.kg-1.pg-1.ml among various animals and was inversely and significantly related to glucagon requirement. SI varied less (approximately 4-fold) and was not associated with glucagon requirement. These observations suggested that interanimal differences in glucose during hormone replacement were the result of substantial differences in GS. In addition, we found the GS of a given animal to be highly associated (P = 0.01) with its fasting glucose level. We conclude that GS varies substantially, and as such may be an important determinant of the fasting glucose level in normal animals.

Key concepts: Glucagon, Internal medicine, Endocrinology, Somatostatin, Insulin, Hormone, Pancreatic hormone, Peptide hormone

Related papers

Back to paper searchBrowse research topicsOriginal source
Hepatic glucagon sensitivity and fasting glucose concentration in normal dogs — Research Paper | ScholarLens