1977Journal of Applied PhysiologyRequires access

Influence of body position on dynamic compliance in young subjects

H. Sasaki, Wataru Hida, Tamotsu Takishima

Open publisher page 18 citations

Abstract

We studied the effect of a postural change from the erect to the supine position on the unevenness of pulmonary ventilation in six normal subjects. Static pressure-volume curves had a similar shape in both positions but the supine curves were shifted such that all transpulmonary pressures were 5-8 cmH2O lower. Dynamic compliance (Cdyn) was measured in seated and supine postures at functional residual capacity (FRC) and also while the seated subjects maintained end-expiratory lung volume at the level of supine FRC. Frequency dependence of Cdyn increased relative to that measured in the seated position at FRC when the subject remained seated but decreased his lung volume, or when he assumed the supine posture. There was no significant difference between Cdyn measured in the supine posture and in the seated at supine FRC. We conclude that the increased frequency dependence seen in the supine posture is largely attributed to the associated decrease of lung volume rather than to position per se.

About this research paper

What this paper is about

We studied the effect of a postural change from the erect to the supine position on the unevenness of pulmonary ventilation in six normal subjects. Static pressure-volume curves had a similar shape in both positions but the supine curves were shifted such that all transpulmonary pressures were 5-8 cmH2O lower. Dynamic compliance (Cdyn) was measured in seated and supine postures at functional residual capacity (FRC) and also while the seated subjects maintained end-expiratory lung volume at the level of supine FRC. Frequency dependence of Cdyn increased relative to that measured in the seated position at FRC when the subject remained seated but decreased his lung volume, or when he assumed the supine posture. There was no significant difference between Cdyn measured in the supine posture and in the seated at supine FRC. We conclude that the increased frequency dependence seen in the supine posture is largely attributed to the associated decrease of lung volume rather than to position per se.

Why it matters

OpenAlex reports 18 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

We studied the effect of a postural change from the erect to the supine position on the unevenness of pulmonary ventilation in six normal subjects. Static pressure-volume curves had a similar shape in both positions but the supine curves were shifted such that all transpulmonary pressures were 5-8 cmH2O lower. Dynamic compliance (Cdyn) was measured in seated and supine postures at functional residual capacity (FRC) and also while the seated subjects maintained end-expiratory lung volume at the level of supine FRC. Frequency dependence of Cdyn increased relative to that measured in the seated position at FRC when the subject remained seated but decreased his lung volume, or when he assumed the supine posture. There was no significant difference between Cdyn measured in the supine posture and in the seated at supine FRC. We conclude that the increased frequency dependence seen in the supine posture is largely attributed to the associated decrease of lung volume rather than to position per se.

Key concepts: Supine position, Functional residual capacity, Lung volumes, Pulmonary compliance, Medicine, Body position, Transpulmonary pressure, Compliance (psychology)

Related papers

Back to paper searchBrowse research topicsOriginal source
Influence of body position on dynamic compliance in young subjects — Research Paper | ScholarLens