1985PubMedRequires access

The study of mechanical properties of rats lungs by whole body plethysmography.

Paulo Hilário Nascimento Saldiva, E Massad, Caldeira Mp, Calheiros Df, Saldiva Cd, Böhm Gm

Open publisher page 5 citations

Abstract

A simple technic for studying the pulmonary mechanics of rats by whole body plethysmography is presented. The parameters measured were: Tidal Volume (TV); Respiratory Frequency (RF); Transpulmonary Basal Pressure (TBP); Dynamic Compliance (Cdyn); Functional Residual Capacity (FRC); Transpulmonary Pressure/Volume curve (TP/V); Forced Expiratory Volume of 1/4 second (FEV 1/4); Expiratory Reserve Volume (ERV); Inspiratory Capacity (IC); Inspiratory Reserve Volume (IRV); Forced Vital Capacity (FVC); Residual Volume (RV); Forced Expiratory Mean Flow between 100-50% (FEMF 100-50), 50-25% (FEMF 50-25) and 25-0% (FEMF 25-0) of the FVC, and Total Lung Capacity (TLC). In order to verify the accuracy of the technic, common male adult Wistar rats, in which pulmonary obstructive disease is normally expected, were first submitted to these functional tests and then to pathological examination. According to the intensity of the morphological pulmonary lesion, the rats were divided in two groups: with and without suppurative pneumopathy. The analysis of the pulmonary function data showed significant decrease of the FEV 1/4 and FEMF 50-25 and increase of the FRC and RV in the groups with pulmonary suppuration. Thus, a discriminant function could be established to characterize the two groups with 100% efficiency. It was concluded that these pulmonary function tests are a valuable and reliable tool to detect lung diseases in rats.

About this research paper

What this paper is about

A simple technic for studying the pulmonary mechanics of rats by whole body plethysmography is presented. The parameters measured were: Tidal Volume (TV); Respiratory Frequency (RF); Transpulmonary Basal Pressure (TBP); Dynamic Compliance (Cdyn); Functional Residual Capacity (FRC); Transpulmonary Pressure/Volume curve (TP/V); Forced Expiratory Volume of 1/4 second (FEV 1/4); Expiratory Reserve Volume (ERV); Inspiratory Capacity (IC); Inspiratory Reserve Volume (IRV); Forced Vital Capacity (FVC); Residual Volume (RV); Forced Expiratory Mean Flow between 100-50% (FEMF 100-50), 50-25% (FEMF 50-25) and 25-0% (FEMF 25-0) of the FVC, and Total Lung Capacity (TLC). In order to verify the accuracy of the technic, common male adult Wistar rats, in which pulmonary obstructive disease is normally expected, were first submitted to these functional tests and then to pathological examination. According to the intensity of the morphological pulmonary lesion, the rats were divided in two groups: with and without suppurative pneumopathy. The analysis of the pulmonary function data showed significant decrease of the FEV 1/4 and FEMF 50-25 and increase of the FRC and RV in the groups with pulmonary suppuration. Thus, a discriminant function could be established to characterize the two groups with 100% efficiency. It was concluded that these pulmonary function tests are a valuable and reliable tool to detect lung diseases in rats.

Why it matters

OpenAlex reports 5 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A simple technic for studying the pulmonary mechanics of rats by whole body plethysmography is presented. The parameters measured were: Tidal Volume (TV); Respiratory Frequency (RF); Transpulmonary Basal Pressure (TBP); Dynamic Compliance (Cdyn); Functional Residual Capacity (FRC); Transpulmonary Pressure/Volume curve (TP/V); Forced Expiratory Volume of 1/4 second (FEV 1/4); Expiratory Reserve Volume (ERV); Inspiratory Capacity (IC); Inspiratory Reserve Volume (IRV); Forced Vital Capacity (FVC); Residual Volume (RV); Forced Expiratory Mean Flow between 100-50% (FEMF 100-50), 50-25% (FEMF 50-25) and 25-0% (FEMF 25-0) of the FVC, and Total Lung Capacity (TLC). In order to verify the accuracy of the technic, common male adult Wistar rats, in which pulmonary obstructive disease is normally expected, were first submitted to these functional tests and then to pathological examination. According to the intensity of the morphological pulmonary lesion, the rats were divided in two groups: with and without suppurative pneumopathy. The analysis of the pulmonary function data showed significant decrease of the FEV 1/4 and FEMF 50-25 and increase of the FRC and RV in the groups with pulmonary suppuration. Thus, a discriminant function could be established to characterize the two groups with 100% efficiency. It was concluded that these pulmonary function tests are a valuable and reliable tool to detect lung diseases in rats.

Key concepts: Functional residual capacity, Transpulmonary pressure, Plethysmograph, Lung volumes, Medicine, Pulmonary compliance, Pulmonary function testing, Cardiology

Related papers

Back to paper searchBrowse research topicsOriginal source
The study of mechanical properties of rats lungs by whole body plethysmography. — Research Paper | ScholarLens