1990•Unpublished venueRequires access

Subattomole Amino Acid Analysis by Laser-Induced Fluorescence: The Sheath Flow Cuvette Meets Capillary Zone Electrophoresis

YF Cheng, N.J. Dovichi

Open publisher page 0 citations

Abstract

Subattomole analysis of fluorescein isothiocyanate (FITC) derivatives of amino acids is produced by combining capillary zone electrophoresis for high-efficiency separation with laser-induced fluorescence for high sensitivity detection. To optimize the separation process, several buffer systems were investigated. A pH 10 carbonate buffer provided good separation of 14 FITC amino acids. Concentration detection limits range from 5 × 10-12 M for alanine to 9 × 10-11 M for lysine, injected onto the column; ∼9 × 10-21 mol of alanine is contained within the ∼1-nL injection volume at the detection limit. The alanine detection limit corresponds to less than 6000 molecules injected onto the column and represents a four order of magnitude improvement in the state of the art for fluorescent detection of amino acids and a six order of magnitude improvement in the state of the art for the detection limit for isothiocyanate derivatives of amino acids.

About this research paper

What this paper is about

Subattomole analysis of fluorescein isothiocyanate (FITC) derivatives of amino acids is produced by combining capillary zone electrophoresis for high-efficiency separation with laser-induced fluorescence for high sensitivity detection. To optimize the separation process, several buffer systems were investigated. A pH 10 carbonate buffer provided good separation of 14 FITC amino acids. Concentration detection limits range from 5 × 10-12 M for alanine to 9 × 10-11 M for lysine, injected onto the column; ∼9 × 10-21 mol of alanine is contained within the ∼1-nL injection volume at the detection limit. The alanine detection limit corresponds to less than 6000 molecules injected onto the column and represents a four order of magnitude improvement in the state of the art for fluorescent detection of amino acids and a six order of magnitude improvement in the state of the art for the detection limit for isothiocyanate derivatives of amino acids.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Subattomole analysis of fluorescein isothiocyanate (FITC) derivatives of amino acids is produced by combining capillary zone electrophoresis for high-efficiency separation with laser-induced fluorescence for high sensitivity detection. To optimize the separation process, several buffer systems were investigated. A pH 10 carbonate buffer provided good separation of 14 FITC amino acids. Concentration detection limits range from 5 × 10-12 M for alanine to 9 × 10-11 M for lysine, injected onto the column; ∼9 × 10-21 mol of alanine is contained within the ∼1-nL injection volume at the detection limit. The alanine detection limit corresponds to less than 6000 molecules injected onto the column and represents a four order of magnitude improvement in the state of the art for fluorescent detection of amino acids and a six order of magnitude improvement in the state of the art for the detection limit for isothiocyanate derivatives of amino acids.

Key concepts: Cuvette, Detection limit, Chromatography, Capillary electrophoresis, Chemistry, Alanine, Amino acid, Fluorescence

Related papers

Back to paper searchBrowse research topicsOriginal source
Subattomole Amino Acid Analysis by Laser-Induced Fluorescence: The Sheath Flow Cuvette Meets Capillary Zone Electrophoresis — Research Paper | ScholarLens