Subattomole Amino Acid Analysis by Laser-Induced Fluorescence: The Sheath Flow Cuvette Meets Capillary Zone Electrophoresis
YF Cheng, N.J. Dovichi
Abstract
YF Cheng, N.J. Dovichi
Abstract
Subattomole analysis of fluorescein isothiocyanate (FITC) derivatives of amino acids is produced by combining capillary zone electrophoresis for high-efficiency separation with laser-induced fluorescence for high sensitivity detection. To optimize the separation process, several buffer systems were investigated. A pH 10 carbonate buffer provided good separation of 14 FITC amino acids. Concentration detection limits range from 5 × 10-12 M for alanine to 9 × 10-11 M for lysine, injected onto the column; ∼9 × 10-21 mol of alanine is contained within the ∼1-nL injection volume at the detection limit. The alanine detection limit corresponds to less than 6000 molecules injected onto the column and represents a four order of magnitude improvement in the state of the art for fluorescent detection of amino acids and a six order of magnitude improvement in the state of the art for the detection limit for isothiocyanate derivatives of amino acids.
A significance statement is not available in the OpenAlex record.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
Subattomole analysis of fluorescein isothiocyanate (FITC) derivatives of amino acids is produced by combining capillary zone electrophoresis for high-efficiency separation with laser-induced fluorescence for high sensitivity detection. To optimize the separation process, several buffer systems were investigated. A pH 10 carbonate buffer provided good separation of 14 FITC amino acids. Concentration detection limits range from 5 × 10-12 M for alanine to 9 × 10-11 M for lysine, injected onto the column; ∼9 × 10-21 mol of alanine is contained within the ∼1-nL injection volume at the detection limit. The alanine detection limit corresponds to less than 6000 molecules injected onto the column and represents a four order of magnitude improvement in the state of the art for fluorescent detection of amino acids and a six order of magnitude improvement in the state of the art for the detection limit for isothiocyanate derivatives of amino acids.
Key concepts: Cuvette, Detection limit, Chromatography, Capillary electrophoresis, Chemistry, Alanine, Amino acid, Fluorescence