2008Unpublished venueRequires access

Biofidelity of rear impact dummies in low speed rear-end impact - comparison of rigid seat and mass production car seat in human volunteers

Kunio Yamazaki, Koshiro Ono, Mitsuru Ishii

Open publisher page 5 citations

Abstract

In test methodologies methodologies for reducing minor neck injuries, the biofidelity of the dummies is of utmost importance, so this study evaluated the biofidelity of rear impact dummies (BioRID-II, RID3D and Hybrid-III) and compared the results with those of human volunteer tests. To evaluate the biofidelity of rear impact dummies, two test series were conducted under the same conditions as with the human volunteer tests at the impact velocity of 8 km/h: the deceleration sled test and the acceleration sled test. In the deceleration sled test, a wooden rigid seat without headrest was mounted to a sled which was moved on ramped rails and collided into a damper. In the acceleration sled test, a mass-production car seat with headrest was mounted to a sled which was accelerated horizontally. In both test series, five tests were conducted for each dummy. In the two test series, the behavior of BioRID-II was very similar to that of the volunteers. In addition, BioRID-II showed good biofidelity for the head angle with respect to T1 (the first thoracic spine), which is considered to be an important characteristic of a rear impact dummy. These results were possible due to the spine structure flexibility of BioRID-II. On the other hand, RID3D, which has flexibility in the neck, needs flexibility between the torso and the lower neck to improve its biofidelity. For Hybrid-III, the dummy showed a very different behavioral response compared to the human volunteers; its biofidelity was lower than that of the rear impact dummies. For the covering abstract see ITRD E144229.

About this research paper

What this paper is about

In test methodologies methodologies for reducing minor neck injuries, the biofidelity of the dummies is of utmost importance, so this study evaluated the biofidelity of rear impact dummies (BioRID-II, RID3D and Hybrid-III) and compared the results with those of human volunteer tests. To evaluate the biofidelity of rear impact dummies, two test series were conducted under the same conditions as with the human volunteer tests at the impact velocity of 8 km/h: the deceleration sled test and the acceleration sled test. In the deceleration sled test, a wooden rigid seat without headrest was mounted to a sled which was moved on ramped rails and collided into a damper. In the acceleration sled test, a mass-production car seat with headrest was mounted to a sled which was accelerated horizontally. In both test series, five tests were conducted for each dummy. In the two test series, the behavior of BioRID-II was very similar to that of the volunteers. In addition, BioRID-II showed good biofidelity for the head angle with respect to T1 (the first thoracic spine), which is considered to be an important characteristic of a rear impact dummy. These results were possible due to the spine structure flexibility of BioRID-II. On the other hand, RID3D, which has flexibility in the neck, needs flexibility between the torso and the lower neck to improve its biofidelity. For Hybrid-III, the dummy showed a very different behavioral response compared to the human volunteers; its biofidelity was lower than that of the rear impact dummies. For the covering abstract see ITRD E144229.

Why it matters

OpenAlex reports 5 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

In test methodologies methodologies for reducing minor neck injuries, the biofidelity of the dummies is of utmost importance, so this study evaluated the biofidelity of rear impact dummies (BioRID-II, RID3D and Hybrid-III) and compared the results with those of human volunteer tests. To evaluate the biofidelity of rear impact dummies, two test series were conducted under the same conditions as with the human volunteer tests at the impact velocity of 8 km/h: the deceleration sled test and the acceleration sled test. In the deceleration sled test, a wooden rigid seat without headrest was mounted to a sled which was moved on ramped rails and collided into a damper. In the acceleration sled test, a mass-production car seat with headrest was mounted to a sled which was accelerated horizontally. In both test series, five tests were conducted for each dummy. In the two test series, the behavior of BioRID-II was very similar to that of the volunteers. In addition, BioRID-II showed good biofidelity for the head angle with respect to T1 (the first thoracic spine), which is considered to be an important characteristic of a rear impact dummy. These results were possible due to the spine structure flexibility of BioRID-II. On the other hand, RID3D, which has flexibility in the neck, needs flexibility between the torso and the lower neck to improve its biofidelity. For Hybrid-III, the dummy showed a very different behavioral response compared to the human volunteers; its biofidelity was lower than that of the rear impact dummies. For the covering abstract see ITRD E144229.

Key concepts: Torso, Acceleration, Hybrid III, Simulation, Engineering, Flexibility (engineering), Neck injury, Poison control

Related papers

Back to paper searchBrowse research topicsOriginal source
Biofidelity of rear impact dummies in low speed rear-end impact - comparison of rigid seat and mass production car seat in human volunteers — Research Paper | ScholarLens