[Application of comparison method in internal quality control of hematology analyzer by using fresh blood].

Wenjun Wang, Peipei Wang, Xuefen Li, Xia-qin Ge, Ming Tong, Xichao Guo

Open publisher page 1 citations

Abstract

OBJECTIVE: To investigate the comparison method on internal control of hematology analyzer by using fresh blood. METHODS: The hematology analyzer with well function was selected as the reference analyzer, fresh blood samples from healthy subjects were measured by reference analyzer and the values were used to calibrate compared hematology analyzers. The acceptable limits of relative deviation of WBC,RBC, HGB,HCT, PLT were established by comparative experiments during three months. The results of fresh blood samples from patients with low/medium/high levels measured by compared analyzer were compared with those from reference analyzer, the relative deviation of WBC, RBC, HGB, HCT, PLT was calculated respectively. The internal quality control charts in laboratory information system were established, with date as x-axis, relative deviation as y-axis. The acceptable relative deviation limits were set to be +/-2 s, and to be used for laboratory quality control. RESULT: The relative deviation of WBC, RBC, HGB, HCT, PLT with high, medium, low levels were(0.75+/-2.964)%, (1.19+/-2.488)%,(1.43+/-2.439)%; (-0.39+/-1.327)%, (-0.26+/-1.297)%, (-0.35+/-1.095)%û(-0.43+/-1.393)%, (-0.17+/-1.139)%, (0.24+/-1.166)%û(-.43+/-1.362)%, (-0.36+/-1.381)%, (-0.57+/-1.299)%û(-0.93+/-4.330)%,(0.04+/-4.118)%, (-0.41+/-4.149)%, respectively in 2006. As the second instrument, the compared analyzer was involved in College of American Pathologists Proficiency Testing with satisfactory results, the bias of WBC,RBC, HGB, HCT, PLT were within (-0.5 approximately 5.1)%, (-1.0 approximately 1.6)%, (-1.7 approximately 1.4)%, (-1.5 approximately 1.3)%, (-4.5 approximately 7.4)%, respectively. CONCLUSION: The quality control on compared hematology analyzer can be effectively, conveniently and economically performed using this method.

About this research paper

What this paper is about

OBJECTIVE: To investigate the comparison method on internal control of hematology analyzer by using fresh blood. METHODS: The hematology analyzer with well function was selected as the reference analyzer, fresh blood samples from healthy subjects were measured by reference analyzer and the values were used to calibrate compared hematology analyzers. The acceptable limits of relative deviation of WBC,RBC, HGB,HCT, PLT were established by comparative experiments during three months. The results of fresh blood samples from patients with low/medium/high levels measured by compared analyzer were compared with those from reference analyzer, the relative deviation of WBC, RBC, HGB, HCT, PLT was calculated respectively. The internal quality control charts in laboratory information system were established, with date as x-axis, relative deviation as y-axis. The acceptable relative deviation limits were set to be +/-2 s, and to be used for laboratory quality control. RESULT: The relative deviation of WBC, RBC, HGB, HCT, PLT with high, medium, low levels were(0.75+/-2.964)%, (1.19+/-2.488)%,(1.43+/-2.439)%; (-0.39+/-1.327)%, (-0.26+/-1.297)%, (-0.35+/-1.095)%û(-0.43+/-1.393)%, (-0.17+/-1.139)%, (0.24+/-1.166)%û(-.43+/-1.362)%, (-0.36+/-1.381)%, (-0.57+/-1.299)%û(-0.93+/-4.330)%,(0.04+/-4.118)%, (-0.41+/-4.149)%, respectively in 2006. As the second instrument, the compared analyzer was involved in College of American Pathologists Proficiency Testing with satisfactory results, the bias of WBC,RBC, HGB, HCT, PLT were within (-0.5 approximately 5.1)%, (-1.0 approximately 1.6)%, (-1.7 approximately 1.4)%, (-1.5 approximately 1.3)%, (-4.5 approximately 7.4)%, respectively. CONCLUSION: The quality control on compared hematology analyzer can be effectively, conveniently and economically performed using this method.

Why it matters

OpenAlex reports 1 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

OBJECTIVE: To investigate the comparison method on internal control of hematology analyzer by using fresh blood. METHODS: The hematology analyzer with well function was selected as the reference analyzer, fresh blood samples from healthy subjects were measured by reference analyzer and the values were used to calibrate compared hematology analyzers. The acceptable limits of relative deviation of WBC,RBC, HGB,HCT, PLT were established by comparative experiments during three months. The results of fresh blood samples from patients with low/medium/high levels measured by compared analyzer were compared with those from reference analyzer, the relative deviation of WBC, RBC, HGB, HCT, PLT was calculated respectively. The internal quality control charts in laboratory information system were established, with date as x-axis, relative deviation as y-axis. The acceptable relative deviation limits were set to be +/-2 s, and to be used for laboratory quality control. RESULT: The relative deviation of WBC, RBC, HGB, HCT, PLT with high, medium, low levels were(0.75+/-2.964)%, (1.19+/-2.488)%,(1.43+/-2.439)%; (-0.39+/-1.327)%, (-0.26+/-1.297)%, (-0.35+/-1.095)%û(-0.43+/-1.393)%, (-0.17+/-1.139)%, (0.24+/-1.166)%û(-.43+/-1.362)%, (-0.36+/-1.381)%, (-0.57+/-1.299)%û(-0.93+/-4.330)%,(0.04+/-4.118)%, (-0.41+/-4.149)%, respectively in 2006. As the second instrument, the compared analyzer was involved in College of American Pathologists Proficiency Testing with satisfactory results, the bias of WBC,RBC, HGB, HCT, PLT were within (-0.5 approximately 5.1)%, (-1.0 approximately 1.6)%, (-1.7 approximately 1.4)%, (-1.5 approximately 1.3)%, (-4.5 approximately 7.4)%, respectively. CONCLUSION: The quality control on compared hematology analyzer can be effectively, conveniently and economically performed using this method.

Key concepts: Hematology analyzer, Spectrum analyzer, Hematology, Medicine, Relative standard deviation, Limits of agreement, Internal medicine, Nuclear medicine

Related papers

Back to paper searchBrowse research topicsOriginal source
[Application of comparison method in internal quality control of hematology analyzer by using fresh blood]. — Research Paper | ScholarLens