Abstract

There is no scientific data on which is the best method and catheter to use in acute urinary retention in males. We therefore compared the efficiency of a size 12 G latex rubber balloon catheter with a similar calibre but more expensive catheter made of polyvinyl-chloride (PVC). A total of 50 patients was studied and a 100% successful catheterisation rate was recorded at first attempt with both catheters, with no significant complications. The importance of the correct management of acute urinary retention, especially adequate analgesia, is stressed and it is concluded that either catheter is satisfactory.

About this research paper

What this paper is about

There is no scientific data on which is the best method and catheter to use in acute urinary retention in males. We therefore compared the efficiency of a size 12 G latex rubber balloon catheter with a similar calibre but more expensive catheter made of polyvinyl-chloride (PVC). A total of 50 patients was studied and a 100% successful catheterisation rate was recorded at first attempt with both catheters, with no significant complications. The importance of the correct management of acute urinary retention, especially adequate analgesia, is stressed and it is concluded that either catheter is satisfactory.

Why it matters

OpenAlex reports 10 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

There is no scientific data on which is the best method and catheter to use in acute urinary retention in males. We therefore compared the efficiency of a size 12 G latex rubber balloon catheter with a similar calibre but more expensive catheter made of polyvinyl-chloride (PVC). A total of 50 patients was studied and a 100% successful catheterisation rate was recorded at first attempt with both catheters, with no significant complications. The importance of the correct management of acute urinary retention, especially adequate analgesia, is stressed and it is concluded that either catheter is satisfactory.

Key concepts: Urinary retention, Medicine, Catheter, Urinary catheter, Urinary catheterization, Surgery, Balloon, Urinary system

Related papers

Back to paper searchBrowse research topicsOriginal source
Acute urinary retention: which catheter? — Research Paper | ScholarLens