1993Southern Medical JournalRequires access

Superiority of Amniotic Fluid Index Over Amniotic Fluid Pocket Measurement for Predicting Bad Fetal Outcome

Alaaeldin A. Youssef, Sayed A. Abdulla, Ezzat H. Sayed, H.T. Salem, Ali M. Abdelalim, Lawrence D. Devoe

Open publisher page 37 citations

Abstract

Semiquantitative amniotic fluid volume (AFV) determination is a component of the fetal biophysical profile (BPP). To assess decreased AVF we did BPPs of 174 fetuses within 1 week of delivery. Two methods were used: measurement of the single largest vertical pocket (oligohydramnios = depth < 1 cm) and the four-quadrant amniotic fluid index (AFI) (oligohydramnios = AFI < or = 5 cm). AFV, as determined by each method, was related to measures of fetal outcome (perinatal mortality, fetal distress, Apgar score, meconium-stained amniotic fluid, and intrauterine growth retardation [IUGR]). The AFI was more sensitive in predicting mortality (87.5%) and the following measures of perinatal morbidity: low 5-minute Apgar score (88.8%), fetal distress during labor (86.6%), meconium-stained amniotic fluid (63.6%), and the presence of IUGR (79.4%). The sensitivity of amniotic fluid pocket measurement of < 1 cm was 75%, 72.2%, 66.6%, 47.7%, and 55.8%, respectively, for the same measures. Using the AFI instead of a single pocket measurement in BPP assessment increased the sensitivity and positive predictive value of the BPP from 64.7% to 76.4% and from 45.8% to 68.4%, respectively. Our data suggest that qualitative AFV measurement using the AFI is superior to that of the single largest pocket in multiple component fetal biophysical testing.

About this research paper

What this paper is about

Semiquantitative amniotic fluid volume (AFV) determination is a component of the fetal biophysical profile (BPP). To assess decreased AVF we did BPPs of 174 fetuses within 1 week of delivery. Two methods were used: measurement of the single largest vertical pocket (oligohydramnios = depth < 1 cm) and the four-quadrant amniotic fluid index (AFI) (oligohydramnios = AFI < or = 5 cm). AFV, as determined by each method, was related to measures of fetal outcome (perinatal mortality, fetal distress, Apgar score, meconium-stained amniotic fluid, and intrauterine growth retardation [IUGR]). The AFI was more sensitive in predicting mortality (87.5%) and the following measures of perinatal morbidity: low 5-minute Apgar score (88.8%), fetal distress during labor (86.6%), meconium-stained amniotic fluid (63.6%), and the presence of IUGR (79.4%). The sensitivity of amniotic fluid pocket measurement of < 1 cm was 75%, 72.2%, 66.6%, 47.7%, and 55.8%, respectively, for the same measures. Using the AFI instead of a single pocket measurement in BPP assessment increased the sensitivity and positive predictive value of the BPP from 64.7% to 76.4% and from 45.8% to 68.4%, respectively. Our data suggest that qualitative AFV measurement using the AFI is superior to that of the single largest pocket in multiple component fetal biophysical testing.

Why it matters

OpenAlex reports 37 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Semiquantitative amniotic fluid volume (AFV) determination is a component of the fetal biophysical profile (BPP). To assess decreased AVF we did BPPs of 174 fetuses within 1 week of delivery. Two methods were used: measurement of the single largest vertical pocket (oligohydramnios = depth < 1 cm) and the four-quadrant amniotic fluid index (AFI) (oligohydramnios = AFI < or = 5 cm). AFV, as determined by each method, was related to measures of fetal outcome (perinatal mortality, fetal distress, Apgar score, meconium-stained amniotic fluid, and intrauterine growth retardation [IUGR]). The AFI was more sensitive in predicting mortality (87.5%) and the following measures of perinatal morbidity: low 5-minute Apgar score (88.8%), fetal distress during labor (86.6%), meconium-stained amniotic fluid (63.6%), and the presence of IUGR (79.4%). The sensitivity of amniotic fluid pocket measurement of < 1 cm was 75%, 72.2%, 66.6%, 47.7%, and 55.8%, respectively, for the same measures. Using the AFI instead of a single pocket measurement in BPP assessment increased the sensitivity and positive predictive value of the BPP from 64.7% to 76.4% and from 45.8% to 68.4%, respectively. Our data suggest that qualitative AFV measurement using the AFI is superior to that of the single largest pocket in multiple component fetal biophysical testing.

Key concepts: Oligohydramnios, Medicine, Amniotic fluid index, Amniotic fluid, Fetal distress, Meconium, Obstetrics, Biophysical profile

Related papers

Back to paper searchBrowse research topicsOriginal source
Superiority of Amniotic Fluid Index Over Amniotic Fluid Pocket Measurement for Predicting Bad Fetal Outcome — Research Paper | ScholarLens