2007AIP conference proceedingsRequires access

Multiphase Flow Measurements by Full Stream Batch Sampling

Dong Wang, Fachun Liang, Xiugang Zhang, Lin Zong-hu

Open publisher page 2 citations

Abstract

A new method of multiphase flow measurements that based on the “extracting and separating method” was proposed in this paper. An extraction flow (or sample) is diverted in a manner of time sharing or full stream batch sampling, then the sample is separated into single phase flows and metered with conventional flow meters, the total flow rates of each phase are determined according to the metered values and the extraction ratios. Because the full stream is conducted to the extraction loop during sampling, no matter what the flow regime of multiphase flow is, the extracted stream (or sample) is always the representative of the total stream and the extraction ratio can keep stable. Experiments were conducted in an air‐water‐oil flow test loop, the inside pipe diameter of the test loop was 50 mm, and the superficial gas velocity varied from 4.5 m/s ∼22m/s, the liquid superficial velocity was in the range of 0.02∼0.3m/s, the oil concentration was in the range of 0.0%∼60% by volume. The flow pattern occurring during the experiments included stratified flow, wave flow and annular flow. The experimental results shown that the full stream batch sample method is feasible to measure the multiphase flow rate, and the average error of flow rates measurements for each phase was less than 3.82%.

About this research paper

What this paper is about

A new method of multiphase flow measurements that based on the “extracting and separating method” was proposed in this paper. An extraction flow (or sample) is diverted in a manner of time sharing or full stream batch sampling, then the sample is separated into single phase flows and metered with conventional flow meters, the total flow rates of each phase are determined according to the metered values and the extraction ratios. Because the full stream is conducted to the extraction loop during sampling, no matter what the flow regime of multiphase flow is, the extracted stream (or sample) is always the representative of the total stream and the extraction ratio can keep stable. Experiments were conducted in an air‐water‐oil flow test loop, the inside pipe diameter of the test loop was 50 mm, and the superficial gas velocity varied from 4.5 m/s ∼22m/s, the liquid superficial velocity was in the range of 0.02∼0.3m/s, the oil concentration was in the range of 0.0%∼60% by volume. The flow pattern occurring during the experiments included stratified flow, wave flow and annular flow. The experimental results shown that the full stream batch sample method is feasible to measure the multiphase flow rate, and the average error of flow rates measurements for each phase was less than 3.82%.

Why it matters

OpenAlex reports 2 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A new method of multiphase flow measurements that based on the “extracting and separating method” was proposed in this paper. An extraction flow (or sample) is diverted in a manner of time sharing or full stream batch sampling, then the sample is separated into single phase flows and metered with conventional flow meters, the total flow rates of each phase are determined according to the metered values and the extraction ratios. Because the full stream is conducted to the extraction loop during sampling, no matter what the flow regime of multiphase flow is, the extracted stream (or sample) is always the representative of the total stream and the extraction ratio can keep stable. Experiments were conducted in an air‐water‐oil flow test loop, the inside pipe diameter of the test loop was 50 mm, and the superficial gas velocity varied from 4.5 m/s ∼22m/s, the liquid superficial velocity was in the range of 0.02∼0.3m/s, the oil concentration was in the range of 0.0%∼60% by volume. The flow pattern occurring during the experiments included stratified flow, wave flow and annular flow. The experimental results shown that the full stream batch sample method is feasible to measure the multiphase flow rate, and the average error of flow rates measurements for each phase was less than 3.82%.

Key concepts: Multiphase flow, Volumetric flow rate, Flow measurement, Flow (mathematics), Two-phase flow, Extraction (chemistry), Sampling (signal processing), Range (aeronautics)

Related papers

Back to paper searchBrowse research topicsOriginal source
Multiphase Flow Measurements by Full Stream Batch Sampling — Research Paper | ScholarLens