Quantifying local cerebral blood flow by N-isopropyl-p-[123I]iodoamphetamine (IMP) tomography.
David E. Kuhl, Jorge R. Barrio, Sung-Cheng Huang, Carl Selin, Robert F. Ackermann, James L. Lear, Jing-Chuan Wu, Tianye Lin, Michael E. Phelps
Abstract
David E. Kuhl, Jorge R. Barrio, Sung-Cheng Huang, Carl Selin, Robert F. Ackermann, James L. Lear, Jing-Chuan Wu, Tianye Lin, Michael E. Phelps
Abstract
A model was validated wherein local cerebral blood flow (LCBF) in humans was quantified by single-photon emission computed tomography (SPECT) with intravenously injected N-isopropyl-p-[123I]iodoamphetamine (IMP) combined with a modification of the classic method of arterial input sampling. After intravenous injection of IMP in rat, autoradiograms of the brain showed activity distributions in the pattern of LCBF. IMP was nearly completely removed on first pass through monkey brain after intracarotid injection (CBF=33 ml/100 g/min) and washed out with a half-time of approximately 1 hr. When the modified method of arterial input and tissue-sample counting applied to dog brain, there was good correspondence between LCBF based on IMP and on that by microsphere injection over a wide flow range. In applying the method to human subjects using SPECT, whole-brain CBF measured 47.2 +/- 5.4 ml/100 g/min (mean +/- s.d., N=5), stable gray-white distinction persisted for over 1 hr, and the half-time for brain washout was approximately 1 hr. Perfusion deficits in patients were clearly demonstrated and quantified, comparing well with results now available from positron ECT.
OpenAlex reports 428 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
A model was validated wherein local cerebral blood flow (LCBF) in humans was quantified by single-photon emission computed tomography (SPECT) with intravenously injected N-isopropyl-p-[123I]iodoamphetamine (IMP) combined with a modification of the classic method of arterial input sampling. After intravenous injection of IMP in rat, autoradiograms of the brain showed activity distributions in the pattern of LCBF. IMP was nearly completely removed on first pass through monkey brain after intracarotid injection (CBF=33 ml/100 g/min) and washed out with a half-time of approximately 1 hr. When the modified method of arterial input and tissue-sample counting applied to dog brain, there was good correspondence between LCBF based on IMP and on that by microsphere injection over a wide flow range. In applying the method to human subjects using SPECT, whole-brain CBF measured 47.2 +/- 5.4 ml/100 g/min (mean +/- s.d., N=5), stable gray-white distinction persisted for over 1 hr, and the half-time for brain washout was approximately 1 hr. Perfusion deficits in patients were clearly demonstrated and quantified, comparing well with results now available from positron ECT.
Key concepts: Cerebral blood flow, Nuclear medicine, Positron emission tomography, Perfusion, Washout, Single-photon emission computed tomography, Iodine-123, Perfusion scanning