1986PubMedRequires access

Assessment of regional cerebral blood flow with 123I amphetamine single photon emission computed tomography in cerebrovascular disease. Semiquantitative analysis comparing IMP SPECT with the 133Xe inhalation method.

Yasuyuki Tsuda, Antje Hartmann, Biersack Hj, E. Valerius, K. Reichmann

Open publisher page 1 citations

Abstract

To compare the capacity of three-dimensional IMP single photon emission computed tomography (SPECT) with that of the two-dimensional 133Xe method in detecting focal perfusion abnormalities in cerebrovascular disease, flow measurements were performed with both methods in twenty patients. In order to enable correlation with 133Xe regional cerebral blood flow (rCBF) IMP SPECT images were subdivided into areas extending from the outer to the inner part corresponding to 32 regions of the 133Xe Cerebrograph. Between IMP counts/pixel and 133Xe rCBF, inter-hemispheric ratios correlated better in severe ischemia. Absolute mean values correlated in the affected hemisphere but not in the unaffected hemisphere. Regional evaluations revealed tendencies of IMP SPECT to be sensitive for low flow areas but to underestimate high flow areas, i. e. the 'luxury perfusion syndrome', as compared with the 133Xe method.

About this research paper

What this paper is about

To compare the capacity of three-dimensional IMP single photon emission computed tomography (SPECT) with that of the two-dimensional 133Xe method in detecting focal perfusion abnormalities in cerebrovascular disease, flow measurements were performed with both methods in twenty patients. In order to enable correlation with 133Xe regional cerebral blood flow (rCBF) IMP SPECT images were subdivided into areas extending from the outer to the inner part corresponding to 32 regions of the 133Xe Cerebrograph. Between IMP counts/pixel and 133Xe rCBF, inter-hemispheric ratios correlated better in severe ischemia. Absolute mean values correlated in the affected hemisphere but not in the unaffected hemisphere. Regional evaluations revealed tendencies of IMP SPECT to be sensitive for low flow areas but to underestimate high flow areas, i. e. the 'luxury perfusion syndrome', as compared with the 133Xe method.

Why it matters

OpenAlex reports 1 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

To compare the capacity of three-dimensional IMP single photon emission computed tomography (SPECT) with that of the two-dimensional 133Xe method in detecting focal perfusion abnormalities in cerebrovascular disease, flow measurements were performed with both methods in twenty patients. In order to enable correlation with 133Xe regional cerebral blood flow (rCBF) IMP SPECT images were subdivided into areas extending from the outer to the inner part corresponding to 32 regions of the 133Xe Cerebrograph. Between IMP counts/pixel and 133Xe rCBF, inter-hemispheric ratios correlated better in severe ischemia. Absolute mean values correlated in the affected hemisphere but not in the unaffected hemisphere. Regional evaluations revealed tendencies of IMP SPECT to be sensitive for low flow areas but to underestimate high flow areas, i. e. the 'luxury perfusion syndrome', as compared with the 133Xe method.

Key concepts: Medicine, Single-photon emission computed tomography, Cerebral blood flow, Perfusion, Emission computed tomography, Nuclear medicine, Inhalation, Blood flow

Related papers

Back to paper searchBrowse research topicsOriginal source
Assessment of regional cerebral blood flow with 123I amphetamine single photon emission computed tomography in cerebrovascular disease. Semiquantitative analysis comparing IMP SPECT with the 133Xe inhalation method. — Research Paper | ScholarLens